- Research
- Open access
- Published:
A pilot study evaluating the Calibrated Automated Thrombogram assay and application of plasma-thromboelastography for detection of hemostatic aberrations in horses with gastrointestinal disease
BMC Veterinary Research volume 17, Article number: 346 (2021)
Abstract
Background
Critically ill horses, such as horses with gastrointestinal (GI) disease, often suffer from hemostatic aberrations. Global hemostatic tests examining the initiation of coagulation, clot strength and fibrinolysis, such as the Calibrated Automated Thrombogram (CAT) and plasma-thromboelastography (TEG) have not been evaluated in horses. This study aimed to evaluate CAT and apply plasma-TEG in horses.
Test performance of CAT was evaluated on equine platelet poor plasma with intra- and inter-assay variability (CV) and a heparin dilution curve. To examine clinical performance of both tests, group comparisons were assessed comparing healthy horses, horses with mild and severe GI disease with both CAT and plasma-TEG.
Results
For CAT, intra- and inter-assay CVs were established for lag-time (1.7, 4.7%), endogenous thrombin potential (1.6, 4.6%), peak (2.6, 3.9%) and time to peak (ttPeak) (1.9, 3.4%). Increasing heparin concentrations led to the expected decrease in thrombin generation. In the group comparison analysis, CAT showed significant higher peak (p = 0.04) and ttPeak (p = 0.008) in the severe GI disease group compared to horses with mild GI disease and healthy horses, respectively. Plasma-TEG showed an increased angle (p = 0.032), maximum amplitude (p = 0.017) and shear elastic force (G) (p = 0.017) in the severe GI disease group compared to healthy horses.
Conclusions
CAT performed well in horses. Both CAT and plasma-TEG identified hemostatic aberrations in horses with severe GI disease compared to healthy horses. Further studies including more horses, are needed to fully appreciate the use of CAT and plasma-TEG in this species.
Background
Critically ill horses, such as horses with ischemic or inflammatory gastrointestinal (GI) disease, often suffer from marked hemostatic aberrations [1,2,3,4,5]. The most frequent hemostatic aberration is a hypercoagulable state with a decrease in platelet (PLT) count, an increase in thrombin–antithrombin (TAT) complexes, a prolonged prothrombin (PT) and activated partial thromboplastin (aPTT) time, decreased anti-thrombin (AT) and increased D-dimer [1, 2, 4,5,6]. When this consumption coagulopathy overwhelms the inhibitory system, the coagulopathy is then said to be uncompensated, and an imbalance arises, that can lead to disseminated intravascular coagulation (DIC) and thrombus formation. This hypercoagulable state can however also progress into a hypocoagulable state in the later stages of the disease process due to the depletion of procoagulant factors [3]. This proves that coagulopathies are dynamic and complex pathophysiologic processes. This might explain why one study looking at TEG and conventional hemostatic markers found horses with severe GI disease (ischemic and inflammatory lesions) to be hypocoagulable [3], whereas another study looking at TEG and conventional hemostatic markers suggested horses with severe GI disease (ischemic and inflammatory lesions) to be hypercoagulable [2]. There has however only been moderate progression in the use of more advanced diagnostic global hemostatic tests in horses [2, 3, 7,8,9,10,11,12,13,14], with more conventional hemostatic markers such as PLT count, aPTT, PT, AT, fibrinogen, and D-dimer concentration still being the most commonly reported parameters [15, 16].
These hemostatic parameters, however, have some limitations since they are snapshots of different aspects of the hemostatic process. Global hemostatic tests such as thrombin generation time or thromboelastography (TEG) on the other hand are dynamic and cover the entire hemostatic process from initiation to clot development and fibrinolysis [17, 18]. Whole blood-TEG has been evaluated in equine medicine in horses suffering from non-strangulating and non-inflammatory GI disorders such as large colon impactions, inflammatory GI disorders such as enterocolitis, and ischemic GI lesions such as intestinal volvulus [2, 3, 7, 19]. One drawback for this method is that TEG should be analyzed with a fixed storage time of ideally 30 min post-sampling in horses to avoid unnecessary time-related aberrations in the TEG parameters [8]. This shortness in time may defer or reduce the applicability of whole blood-TEG in clinical practice as horses are required to be in a hospital setting for the analysis to be performed. If plasma-based global hemostatic tests could replace the whole blood-TEG, this might improve the applicability of the tests in a clinical setting in equine medicine. TEG analyzed with citrated plasma (plasma-TEG) has been investigated in a couple of species. Plasma-TEG was successfully applied in dogs looking at biological variation [20], while in septic pigs plasma-TEG was shown to display a similar increased hemostatic response as identified with whole blood-TEG [21]. In human medicine, plasma-TEG has been applied in studies examining the TEG device, but also in experimental human endotoxemia [22, 23]. Although plasma-TEG is devoid of the cellular components of hemostasis, the coagulation factors and fibrinogen concentration are still present, and changes in test parameters may still be of interest in patients at risk of hemostatic imbalance.
The plasma based thrombin generation time using the Calibrated Automated Thrombogram (CAT) assay, has previously been investigated in both humans [10, 24, 25] and dogs [13, 26]. CAT permits the direct measurement of thrombin generation in a more physiological setting than conventional clotting assays. In humans, it is considered valuable for the study of hypo- and hypercoagulation [10, 27, 28] and has been recommended for assessing patients with venous thromboembolisms [24], evaluating the prognosis in patients with myocardial infarcts [29], and monitoring anticoagulant therapy [10, 13]. An extensive search through the current literature did not identify the use of the CAT assay in horses.
The aim of the present study was, therefore, to evaluate the performance of the CAT assay in equine citrated platelet poor plasma (PPP) and to apply plasma-TEG as an alternative to whole blood-TEG.
Our hypotheses were that the CAT assay would show a high degree of validity and reliability, that both assays would be applicable in equine PPP, and that hemostatic aberrations would be detectable in horses with GI disease compared to clinically healthy horses.
Results
Demographic data regarding the included horses in the three groups are displayed in Table 1.
It was possible to use the CAT assay in the horses. Intra-assay coefficient of variation ranged from 1.6–2.6% and inter-assay coefficient of variability from 3.4–4.7% for lag-time, ETP, peak, and ttPeak, respectively (Table 2).
Increasing concentrations of unfractionated heparin resulted in decreasing thrombin generation except for the two concentrations 0.01125 U/ml and 0.0225 U/ml where there was a slight increase in peak and ETP compared to the trace with a heparin concentration of 0.0 U/mL (Fig. 1, supporting information Table 1 s). Heparin concentrations higher than 0.18 U/ml completely inhibited thrombin generation.
Comparing the CAT assay results for the three groups of horses, significant differences were found in peak (p = 0.04) and ttPeak (p = 0.01) (Table 3).
Post hoc analyses identified a significantly higher peak in horses with severe GI disease compared to horses with mild GI disease (p = 0.04). A significantly lower ttPeak was seen in horses with severe GI disease compared to the clinically healthy horses (p = 0.008) (Fig. 2).
The plasma-TEG ran successfully in all horses with the exception of not reaching K-values in 12/34 horses. Significant differences were seen for α (p = 0.016), MA (p = 0.023) and G (p = 0.022) between the three groups of horses, with post hoc analysis identifying the differences between horses with severe GI disease and clinically healthy horses (α: p = 0.032; MA: p = 0.017; G: p = 0.017) (Fig. 3 and Table 3).
No significant differences in whole blood-TEG parameters were detected between the three groups of horses (Table 4). When comparing whole blood-TEG and plasma-TEG a significantly lower α (p = 0.003), MA (p < 0.0001) and G (p < 0.0001) were found for plasma-TEG.
There were no differences identified between the 3 groups of horses for fibrinogen concentration, aPTT, PT, or AT. Whereas for D-dimer, a significant difference was found between groups (p < 0.0001), with post hoc analysis identifying a difference both between horses with severe and mild GI disease (p = 0.0084) and between severe GI disease and clinically healthy horses (p < 0.0001) (Table 4).
Correlation analyses between plasma-TEG MA and fibrinogen and between plasma-TEG G and fibrinogen both revealed a moderate and significant Spearman’s correlation coefficient (r) of 0.61 (95% CI: 0.33–0.79, p = 0.0001).
Discussion
CAT ran successfully on equine citrated PPP with satisfactory repeatability based on intra- and inter-assay coefficient of variations for both lag-time, ETP, peak, and ttPeak all below the accepted limit of 5% [30].
In the CAT assay the PPP trigger reagent with 5 pM tissue factor was applied to initiate the thrombin generation process, similarly to what has previously been applied in humans [31] and dogs [32]. The manufacturer provides three different triggering reagents with either 1 pM (PPP low), 5pM (PPP) or 20 pM (PPP high) tissue factor [33]. In human research, the PPP low and high are used in hemophilic patients or patients treated with anticoagulant therapy, respectively. In a recent study in cats [34], all three PPP trigger reagents were tested in depth. Based on performance of the three triggering reagents, PPP low was selected as the most appropriate for the feline species. It is possible that more subtle hemostatic aberrations between healthy horses and horses with severe GI disease could have been detected, if a similar set up had been applied in our study. This needs to be investigated further in future studies.
Endogenous thrombin potential did not differ between horses with severe GI disease and healthy horses. While some consider ETP a more consistently predictive parameter for hemostatic aberrations compared to the remaining CAT parameters, others report an equal importance of lag-time, peak, and ttPeak in the CAT assay [26, 32, 35]. In humans an increased peak and ttPeak has been found as a sign of hypercoagulability in patients with both inherited and acquired hemostatic disorders [36, 37]. We did not expect horses with mild GI disease to have hemostatic aberrations when looking at group comparison, but, surprisingly, it was not possible to distinguish horses with severe and mild GI disease with the global hemostatic tests, apart from peak in the CAT assay. This might have been the result of our two groups with GI disease having disease processes that were too similar concerning their pathophysiology even though we intended to include horses with different severity of inflammation and ischemia. Nevertheless, several parameters were significantly different in both the CAT assay and the plasma-TEG between healthy horses and horses with severe GI disease without being mirrored in the whole blood-TEG. Furthermore, the defrosting and centrifugation process in the CAT assay and plasma-TEG could activate the low number of existing platelets as well as procoagulant platelet micro-particles [38]. Potentially, this could contribute to the initiation phase of plasma-based tests and perhaps affect all parameters in the CAT assay as well as α, K, MA, and G in the plasma-TEG. In people, platelet microparticles are known to contribute to a prothrombotic state in different types of GI diseases [39, 40]. Microparticles were not measured in this study, but it could be speculated that horses with severe GI disease would have a higher concentration of platelet microparticles and thus be more procoagulant than healthy horses. In humans a shorter R and K value and an increased angle degree and MA has been found as a sign of hypercoagulability [41, 42].
Although the plasma-TEG was analyzed in all horses, the K parameter did not produce a reading in 12 of these. This is not a problem of clinical relevance, as it is caused by the fact that the pre-set standard value for K in the TEG machine is defined in the software as the time to clot strength at 20 mm based on human whole blood measurements and due to the narrower tracing of the plasma-TEG, this was not achieved in all cases. In general, the plasma-TEG readings had a lower α, MA, and G compared to whole blood TEG, which likely is due to the different composition of PPP compared to whole blood, probably most importantly the lack of platelets.
Contrary to what have been found in previous studies [2, 3, 43], no differences were identified between the three groups of horses when analyzed with whole blood-TEG. The reason for this is not entirely clear. It is most likely due to the complexity of dealing with coagulopathies [3].
In TEG, MA and G are the comprehensive assessment of the fibrinogen function and concentration combined with the platelet count [44]. When analyzing plasma-TEG using PPP, it could thus be claimed that MA and G of such an assay are no more than an elaborate fibrinogen analysis. In the present study, there was a positive correlation between fibrinogen, MA and G. However, as opposed to plasma-TEG MA and G measured by plasma-TEG, the fibrinogen concentration alone was not able to detect a difference between the three groups of horses. Plasma-TEG has still not been validated extensively in veterinary medicine and whether the plasma-TEG is a more sensitive assay than measuring the fibrinogen concentration on its own remains to be fully elucidated.
The decreased ttPeak and elevated peak for the CAT assay and an elevated angle degree, MA and G for the plasma-TEG in the severe GI disease group corresponds well. Both support a hypercoagulable state which was what we expected looking at the existing literature [2, 6]. For the routine coagulation markers an increased D-dimer was additionally seen in the severe GI disease group, which also supports the finding of a hypercoagulable state [4, 5]. It thus seems that horses with severe GI disease suffers from a hypercoagulable state which in a clinical setting can be evaluated with the use of the CAT assay and plasma-TEG.
The main limitation of the present study is the low number of horses in each group and the variability of the disease processes within each group. The low number of horses was a result of the study being conducted as a pilot study. However, the presented preliminary results do suggest that these global hemostatic tests could be of value in horses and it would be of interest to explore these assays in more detail. Studies could focus on applying the tests to larger groups of horses, horses with visible thromboembolic disease or bleeding disorders to fully examine the potential of both the CAT assay and plasma-TEG in equine medicine.
Conclusion
The CAT assay performed well in horses with intra- and inter-assay coefficients of variation below the accepted limits and are thus reliable. Additionally the heparin dilution curve showed that the CAT assay is valid in horses. The CAT assay and plasma-TEG were applicable for use in equine citrated PPP and both assays showed hemostatic aberrations in horses with GI disease. Except for ttPeak in the CAT assay, the assays could not distinguish mild from severe GI disease.
Methods
This study was conducted as a pilot study. All samples were collected at The Large Animal Teaching Hospital at The University of Copenhagen, Denmark, in 2018. Approval was obtained from the ethical board of the Department of Veterinary Clinical Sciences, University of Copenhagen, as was written consent from the owners of the horses.
Study design
For the evaluation of the CAT assay, intra- and inter-assay coefficients of variation were established in order to establish the reliability of the test in equine PPP. This was performed based on replicate measurements on pooled plasma from 10 clinically healthy horses analyzed 10 times on the same day and once daily for 10 consecutive days. To confirm the capacity of the human CAT assay to measure equine thrombin in PPP and thus establish the validity of the test, unfractionated heparin was added in decreasing concentrations to aliquots of the plasma pool: 0.0, 0.01125, 0.0225, 0.045, 0.09, 0.18, 0.37, 0.75, 1.5 and 3.0 U/mL [45,46,47].
To examine if these global hemostatic tests deviated in horses with GI disease, group comparisons of both the CAT assay, plasma-TEG, and whole blood-TEG were performed, comparing horses with severe and mild GI disease to healthy horses. The purpose of a group comparison is to detect differences between healthy and clearly sick individuals and is defined as a phase II of test validation [48]. This is performed before proceeding to the more complex phase III involving several different disease and severity groups. We would expect horses with severe GI disease to be hypercoagulable in comparison to clinically healthy horses and horses with mild GI disease.
Whole blood-TEG and the individual hemostatic parameters; D-dimer, fibrinogen, aPTT, PT, and AT were analyzed in the 3 groups of horses in order to compare them to the new global hemostatic tests.
Horses
Three groups of horses were included in the study: Clinically healthy, mild GI disease, and severe GI disease. The clinically healthy group included adult horses (> 1 year of age) deemed healthy based on clinical examination, complete blood count (CBC) and serum biochemistry profiles, including lactate and the acute phase proteins serum amyloid A (SAA) and fibrinogen concentration being within normal reference intervals. All horses in this group were owned and stabled by The Large Animal Teaching Hospital at The University of Copenhagen. Blood from horses in this group were used in both the intra- and inter-CV studies, the heparin dilution curve and the group comparison. Horses included in the two GI disease groups consisted of adult horses (> 1 year of age) admitted to The Large Animal Teaching Hospital with acute abdominal pain in the period March through June 2018. All samples from hospital patients were collected at admission as part of the initial diagnostic work-up, before placement of intravenous-catheters or administration of any treatments. Horses were assigned to the mild GI disease group if the horses had non-strangulating intestinal obstructions or displacements without signs of secondary inflammation or ischemia of the intestines. Conversely, horses were placed in the severe GI disease group if the horses had inflammatory or strangulating intestinal diseases with ischemia of the intestine. Grouping of the horses was based on clinical signs (heart rate, respiratory rate, temperature and mucous membrane color), CBC, serum biochemistry including SAA, fibrinogen, rectal palpation, naso-gastric intubation, and, where appropriate, abdominocentesis, transabdominal ultrasonography, surgery and post-mortem findings. Horses were considered to have systemic inflammation when there was both clinical or post mortem signs of inflammation like fever or edema in the intestinal wall and inflammatory changes in the blood samples such as leukopenia and increased SAA. Horses were considered to have intestinal ischemia when a segment of the intestine was found to be strangulated and with circulatory changes at surgery or post mortem. Mares included in the study all were reproductively inactive at the sampling point.
Blood sample handling and routine blood analysis
Blood samples were collected by jugular venipuncture using a 21 g needle and a vacutainer system (BD, Franklin Lakes, NJ). Blood tubes (BD, Franklin Lakes, NJ) were collected in the recommended order [49] starting with the 3.2% 0.109 M sodium citrate tubes in a 1:9 ratio citrate/blood, then serum separator tubes, and finally EDTA tubes. A total of 4 sodium citrate, 1 serum and 1 EDTA tubes were obtained in that order, with the first sodium citrate tube being discarded [49]. The remaining three sodium citrate blood tubes were used for hemostatic assays, while the serum and EDTA tubes were used for the routine biochemistry analysis and CBC (ADVIA 2120i, Siemens Healthcare A/S, Ballerup, Denmark) including a blood smear evaluation, at the hospital’s Diagnostic Laboratorium. The serum and EDTA samples were stored at 4 °C until analysis.
Whole blood TEG with diluted tissue factor (TF) was measured 30 min after sampling in all horses. Platelet poor plasma (PPP) was created within a maximum of 1 h by centrifugation of the sodium citrate tubes at room temperature at 2000 g for 15 min [13].. The PPP was stored at -80 °C until batch analysis of plasma-TEG, CAT, d-dimer, fibrinogen, aPTT, PT, and AT. Samples were thawed in a water bath for 4 min at 37 °C and then thoroughly mixed [49]. A platelet count below 10 × 109/L [50] in the PPP was ensured by platelet measurement prior to hemostatic analysis (ADVIA 2120i, Siemens Healthcare A/S, Ballerup, Denmark).
Hemostatic assays
Thrombin generation was measured with the CAT assay. The following four parameters were evaluated: Lag-time (min), which is the time until 1/6 of the total thrombin concentration is reached; the endogenous thrombin potential (ETP) (nM/min), which represents the total amount of thrombin generated; peak (nM), which is the maximal thrombin concentration, and time to peak (ttPeak) (min) (Thrombinoscope BV, Maastricht, The Netherlands). The Thrombinoscope software is for now only intended for research purposes.
The assay was activated by a manufacturer-supplied trigger solution (PPP reagent) (Triolab AS, Denmark). The measuring interval was set to 20 s, the temperature to 37.5 °C, and the measured time to 45 min. All analyses were performed in triplicates. In each well 80 μl of citrated plasma was added to 20 μl of either the activator solution or thrombin calibrator solution as per the manufacturers recommendation and described previously [13]. The activator solution used contained 5 pM TF and 4 μM phospholipids. Thrombin generation was activated as per the manufacturers (Thrombinoscope BV, Maastricht, The Netherlands) instruction by adding 20 μl of FluCa consisting of Fluo-Buffer containing CaCl2 and a fluorescent, and read by an automated highly specific plate reader.
Both plasma-TEG and whole blood-TEG analyses were performed using a computerized thromboelastograph (TEG 5000 Haemostasis Analyzer, Haemoscope Corporation, Illinois, USA). The TEG machines were evaluated prior to daily use with the E-test, which is an electronic quality control. The following TEG parameters were recorded: Split point (SP) which is time to initial conversion of fibrinogen to fibrin; reaction time (R) which is time to initial fibrin clot formation; Clotting time (K) which is the time from initial clot formation until reaching a predetermined level of clot strength (20 mm); Angle (α) which represents the speed of fibrin build up and cross-linking; Maximum amplitude (MA) which represents the maximum clot strength; Shear elastic modulus strength (G) which is a linear function of the MA and considered a measure of global clot strength [51] and degree of fibrinolysis at 30 min (LY30%) and 60 min (LY60%) after MA. The analyses were run as per the manufacturer’s protocol for 2 h. Hypercoagulability for the CAT assay was defined as a shortened lagtime, ttPeak and a higher ETP and Peak compared to the clinically healthy group with one or more altered variable [52]. For TEG hypercoagulability was defined as a shorter R and K value and an increased angle degree, MA, and G (with any ≥1 index being abnormal) compared to the clinically healthy group. For both tests, the opposite situation was defined as hypocoagulability [3, 53,54,55].
Fibrinogen was measured with a PT-based assay using HemosIL RecombiPlastin on an ACL Top 500 (ILS Danmark, Allerød, Denmark). D-dimer, aPTT, PT, and AT were measured on the automated machine STAGO STA Satellite coagulation analyzer (Triolab, Brøndby, Denmark) with different assays for each parameter according to the manufacturers recommendations. D-dimer was analyzed with STA-Liatest D-Di + which is a photometric antibody-antigen assay based on murine D-dimer antibodies [16, 56], aPTT with STA-Cephascreen using kefalin as an activator which together with PT is a coagulometric assay, PT with STA-NeoPTimal using rabbit thromboplastin, and AT with STA-Stachrom ATIII using bovine thrombin which is a chromogenic assay [16].
Statistical analysis
Intra- and inter-assay coefficient of variation levels were calculated using Microsoft Excel 2016 (Washington, USA), and levels below 5% were considered acceptable [30]. Remaining analyses were performed using GraphPad Prism 8.3.0 (San Diego, California, USA).
Normality was assessed by the D’Agostino-Pearsons K-squared test. Comparisons between the three groups of horses were performed using a one-way ANOVA or a Kruskal-Wallis test depending on normality of data. As a post hoc test, either Tukey’s multiple comparisons test or Dunn’s multiple comparisons test was applied. Correlation tests (Spearman) between plasma-TEG MA, plasma-TEG G, and fibrinogen concentration were performed in order to evaluate whether these values were connected. The probability of significance was set at a level of < 0.05.
Availability of data and materials
If deemed relevant or is of interest raw data can be submitted.
Abbreviations
- α:
-
Angle degree (TEG)
- aPTT:
-
Activated partial thromboplastin time
- AT:
-
Anti-thrombin
- BW:
-
Body weight
- CAT:
-
Calibrated Automated Thrombogram
- CBC:
-
Complete blood count
- CV:
-
Coefficients of variation
- DIC:
-
Disseminated intravascular coagulation
- ETP:
-
Endogenous thrombin potential (CAT)
- G:
-
Shear elastic force (TEG)
- GI:
-
Gastrointestinal
- K:
-
Clotting time (TEG)
- LY30%:
-
Fibrinolysis at 30 min after MA (TEG)
- LY60% :
-
Fibrinolysis at 60 min after MA (TEG)
- MA:
-
Maximum amplitude (TEG)
- PLT:
-
Platelet
- PPP:
-
Platelet poor plasma
- PT:
-
Prothrombin time
- R:
-
Reaction time (TEG)
- SAA:
-
Serum amyloid A
- SP:
-
Split point (TEG)
- TAT:
-
Thrombin–antithrombin
- TEG:
-
Thromboelastography
- TF:
-
Tissue factor
- ttPeak:
-
Time to peak (CAT)
- WB-TEG:
-
Whole blood-thromboelastography
References
Dallap BL, Dolente B, Boston R. Coagulation profiles in 27 horses with large colon volvulus. J Vet Emerg Crit Care. 2003;13(4):215–25.
Dunkel B, Chan DL, Boston R, Monreal L. Association between hypercoagulability and decreased survival in horses with ischemic or inflammatory gastrointestinal disease. J Vet Emerg Crit Care. 2010;24:1467–74.
Epstein KL, Brainard BM, Gomez-Ibanez SE, Lopes MAF, Barton MH, Moore JN. Thrombelastography in horses with acute gastrointestinal disease. J Vet Intern Med. 2011;25:307–14.
Cesarini C, Monreal L, Armengou L, Delgado MÁ, Ríos J, Jose-Cunilleras E. Progression of plasma D-dimer concentration and coagulopathies during hospitalization in horses with colic. J Vet Emerg Crit Care. 2014;24(6):672–80.
Cesarini C, Monreal L, Armengou L, Delgado MÁ, Ríos J, Jose-Cunilleras E. Association of admission plasma D-dimer concentration with diagnosis and outcome in horses with colic. J Vet Intern Med. 2010;24:1490–7.
Monreal L, Cesarini C. Coagulopathies in horses with colic. Vet Clin North Am - Equine Prac. 2009;25(2):247–58. Available from: https://doi.org/10.1016/j.cveq.2009.04.001.
Hyldahl Laursen S, Andersen PH, Kjelgaard-Hansen M, Wiinberg B. Comparison of components of biological variation between 3 equine thromboelastography assays. Vet Clin Pathol. 2013;42(4):443–50.
Leclere M, Lavoie JP, Dunn M, Bédard C. Evaluation of a modified thrombelastography assay initiated with recombinant human tissue factor in clinically healthy horses. Vet Clin Pathol. 2009;38(4):462–6.
Hron G, Kollars M, Binder BR, Eichinger S, Kyrle PA. Identification of patients at low risk for recurrent venous thromboembolism by measuring thrombin generation. JAMA. 2006;296(4):397–402.
Hemker HC, Giesen P, AlDieri R, Regnault V, De Smed E, Wagenvoord R, et al. The Calibrated Automated Thrombogram (CAT): a universal routine test for hyper- and hypocoagulability. Pathophysiol Haemost Thromb. 2002;32(5–6):249–53.
Deppe AC, Weber C, Zimmermann J, Kuhn EW, Slottosch I, Liakopoulos OJ, et al. Point-of-care thromboelastography/thromboelastometry-based coagulation management in cardiac surgery: a meta-analysis of 8332 patients. J Surg Res [Internet]. 2016;203(2):424–33. Available from: https://doi.org/10.1016/j.jss.2016.03.008.
Fenty RK, Delaforcade AM, Shaw SP, Toole TEO. Identification of hypercoagulability in dogs with primary immune-mediated hemolytic anemia by means of thromboelastography. J Am Vet Med Assoc. 2011;238(4):463–7.
Allegret V, Dunn M, Bédard C. Monitoring unfractionated heparin therapy in dogs by measuring thrombin generation. Vet Clin Pathol. 2011;40(1):24–31.
Scruggs JL, Flatland B, Mccormick KA, Reed A. Biological variation of thromboelastrography variables in 10 clinically healthy horses. J Vet Emerg Crit Care. 2016;26(1):80–4.
Dallap BL. Coagulopathy in the equine critical care patient. Vet Clin North Am - Equine Pract. 2004;20(1):231–51.
Pihl TH, Nielsen MK, Jacobsen S. Changes in hemostatic indices in foals naturally infected with strongylus vulgaris. J Equine Vet Sci. 2017;54:1–7. Available from: https://doi.org/10.1016/j.jevs.2017.02.002.
Lancé MD. A general review of major global coagulation assays: thrombelastography, thrombin generation test and clot waveform analysis. Thromb J. 2015;13(1):1–6.
Spahn DR, Bouillon B, Cerny V, Coats TJ, Duranteau J, Fernández-mondéjar E, et al. Management of bleeding and coagulopathy following major trauma: an updated European guideline. Crit Care. 2013;17(2):R76. https://doi.org/10.1186/cc12685.
Mendez-angulo JL, Mudge MC, Vilar P, Stingle N, Couto CG. Thromboelastography in healthy horses and horses with inflammatory gastrointestinal disorders and suspected coagulopathies. J Vet Emerg Crit Care. 2010;20(5):488–93.
Wiinberg B, Jensen AL, Kjelgaard-Hansen M, Rojkjaer R, Johansson PI, Gade LP, et al. Study on biological variation of haemostatic parameters in clinically healthy dogs. Vet J. 2007;174(1):62–8.
Krogh AK, Brunse A, Thymann T, Kristensen AT, Nielsen LN. Plasma thromboelastography in septic preterm pigs and full-term pigs at birth and 11 days post-partum. In: Joint Congress of Veterinary Pathology and Veterinary Clinical Pathology 25–28 September 2019 | Arnhem, the Netherlands; 2019. p. 287.
Contreras-García A, Merhi Y, Ruiz JC, Wertheimer MR, Hoemann CD. Thromboelastography (TEG) cups and pins with different PECVD coatings: effect on the coagulation cascade in platelet-poor blood plasma. Plasma Process Polym. 2013;10(9):817–28.
Ostrowski SR, Berg RMG, Windeløv NA, Meyer MAS, Plovsing RR, Møller K, et al. Discrepant fibrinolytic response in plasma and whole blood during experimental endotoxemia in healthy volunteers. PLoS One. 2013;8(3)1-9. https://doi.org/10.1371/journal.pone.0059368.
Wexels F, Dahl OE, Pripp AH, Seljeflot I. Thrombin generation in patients with suspected venous thromboembolism. Clin Appl Thromb. 2017;23(5):416–21.
Dargaud Y, Wolberg AS, Luddington R, Regnault V, Spronk H, Baglin T, et al. Evaluation of a standardized protocol for thrombin generation measurement using the calibrated automated thrombogram: an international multicentre study. Thromb Res. 2012;130(6):929–34. Available from: https://doi.org/10.1016/j.thromres.2012.07.017.
Rose LJ, Dunn ME, Allegret V, Bédard C. Effect of prednisone administration on coagulation variables in healthy beagle dogs. Vet Clin Pathol. 2011;40(4):426–34.
Machlus KR, Colby EA, Wu JR, Koch GG, Key NS, Wolberg S. Effects of tissue factor, thrombomodulin and elevated clotting factor levels on thrombin generation in the calibrated automated thrombogram. Thromb Haemost. 2010;102(5):936–44.
Hemker HC, Giesen P, Al Dieri R, Regnault V, De Smedt E, Wagenvoord R, et al. Calibrated automated thrombin generation measurement in clotting plasma. Pathophysiol Haemost Thromb. 2003;33(1):4–15.
Hudák R, Székely EG, Kovács KR, Nagy A, Hofgárt G, Berényi E, et al. Low thrombin generation predicts poor prognosis in ischemic stroke patients after thrombolysis. PLoS One. 2017;12(7):1–13.
Jensen AL, Kjelgaard-hansen M. Diagnostic Test Validation. Schalm’s Vet Hematol. 2010;6:1027–33.
Jeong JC, Kim JE, Ryu JW, Joo KW, Kim HK. Plasma haemostatic potential of haemodialysis patients assessed by thrombin generation assay: hypercoagulability in patients with vascular access thrombosis. Thromb Res. 2013;132(5):604–9. Available from: https://doi.org/10.1016/j.thromres.2013.09.002.
Rose L, Dunn ME, Bédard C. The effect of canine hyperadrenocorticism on coagulation parameters. J Vet Intern Med. 2013;27:207–11.
Thrombinoscope.com. Thrombinoscope: methods and products. Accessed 13 Mar 2020.
Mischke R, Teuber M, Tiede A. Research in veterinary science measurements of endogenous thrombin potential using the CAT method in cats : reference values and in fl uence of the direct factor Xa inhibitor apixaban. Res Vet Sci. 2019;127(August):113–21. Available from: https://doi.org/10.1016/j.rvsc.2019.08.030.
Mcmichael MA, Brien MO, Smith SA. Hypercoagulability in dogs with blastomycosis. J Vet Intern Med. 2015;29(2):499–504.
Tournier A, Wahl D, Chaouat A, Max JP, Regnault V, Lecompte T, et al. Calibrated automated thrombography demonstrates hypercoagulability in patients with idiopathic pulmonary arterial hypertension. Thromb Res. 2010;126(6):e418–22. Available from: https://doi.org/10.1016/j.thromres.2010.08.020.
Regnault V, Hemker HC, Wahl D, Lecompte T. Phenotyping the haemostatic system by thrombography - potential for the estimation of thrombotic risk. Thromb Res. 2004;114(5–6 SPEC. ISS):539–45.
Stepien E, Gruszczynski K, Kapusta P, Kowalik A, Wybranska I. Plasma centrifugation does not influence thrombin-antithrombin and plasmin-antiplasmin levels but determines platelet microparticles count. Biochem Med. 2015;25(2):222–9.
Chamouard P, Desprez D, Hugel B, Kunzelmann C, Gidon-Jeangirard C, Lessard M, et al. Circulating cell-derived microparticles in Crohn’s disease. Dig Dis Sci. 2005;50(3):574–80.
Pamuk GE, Vural Ö, Turgut B, Demir M, Ümit H, Tezel A. Increased circulating platelet – neutrophil , platelet – monocyte complexes , and platelet activation in patients with ulcerative colitis: a comparative study. Am J Hematol. 2006;81(10):753–9.
Donahue SM, Otto CM. Thromboelastography: a tool for measuring hypercoagulability, hypocoagulability, and fibrinolysis. J Vet Emerg Crit Care. 2005;15(1):9–16.
Kupcinskiene K, Trepenaitis D, Petereit R, Kupcinskas J, Gudaityte R, Maleckas A, et al. Monitoring of hypercoagulability by thromboelastography in bariatric surgery. Med Sci Monit. 2017;23:1819–26.
Müller MC, Meijers JCM, Vroom MB, Juffermans NP. Utility of thromboelastography and/or thromboelastometry in adults with sepsis: a systematic review. Crit Care. 2014;18(1):30.
Salooja N, Perry DJ. Thrombelastography. Blood Coagul Fibrinolysis. 2001;12(5):327–37.
Epstein KL, Brainard BM, Giguere S, Vrono Z, Moore JN. Serial viscoelastic and traditional coagulation testing in horses with gastrointestinal disease. J Vet Emerg Crit Care. 2013;23(5):504–16.
Moore BR, Hinchcliff KW. Heparin: a review of its pharmacology and therapeutic use in horses. J Vet Intern Med. 1994;8(1):26–35.
Duncan SG, Reed SM. Heparin anticoagulant therapy in equine colic. Mod Vet Pract. 1984;65:601–5.
Kjelgaard-Hansen M, Jacobsen S. Assay validation and diagnostic applications of major acute-phase protein testing in companion animals. Clin Lab Med. 2011;31(1):51–70. Available from: https://doi.org/10.1016/j.cll.2010.10.002.
Adcock DM, Hoefner DM, Kottke-Marchant K, Marlar RA, Szamosi DI, Warunek DJ. Collection , transport, and processing of blood specimens for testing plasma-based coagulation assays and molecular hemostasis assays; CLSI approved guideline-fifth edition. H21-A5. Clin Lab Stand Inst. 2008;28(5):H21–A5.
Nielsen LN, Wiinberg B, Kristensen AT. The presence of antiphospholipid antibodies in healthy Bernese Mountain dogs. J Vet Intern Med. 2011;25(6):1258–63.
Hanel RM, Chan DL, Conner B, Gauthier V, Istvan S, Walker JM, et al. Systematic evaluation of evidence on veterinary viscoelastic testing part 4 : definitions and data reporting. J Vet Emerg Crit Care. 2014;24(1):47–56.
Saliba W, Awad K, Ron G, Elias M. The effect of vitamin D supplementation on thrombin generation assessed by the calibrated automated thrombogram. Clin Appl Thromb. 2016;22(4):340–5.
Wang Z, Li J, Cao Q, Wang L, Shan F, Zhang H. Comparison between thromboelastography and conventional coagulation tests in surgical patients with localized prostate cancer. Clin Appl Thromb. 2018;24(5):755–63. Available from: https://doi.org/10.1177/1076029617724229.
Lemon AV, Goddard A, Hooijberg EH. Effects of storage time and temperature on thromboelastographic analysis in dogs and horses. Vet Clin Pathol. 2021;50(1):9–19.
Thakur M, Ahmed AB. A review of thromboelastography. Int J Perioper Ultrasound Appl Technol. 2012;1(1):25–9.
Armengou L, Monreal L, Tarancón I, Navarro M, Ríos J, Segura D. Plasma D-dimer concentration in sick newborn foals. J Vet Intern Med. 2008;22:411–7.
Acknowledgements
The authors are grateful to medical laboratory technologist Louise Bochsen and to laboratory technician Tina Roust from the Department of Veterinary Clinical Sciences, Faculty of Health and Medical Sciences (SUND), University of Copenhagen, Denmark for their laboratory assistance during this study and to the horse owners who kindly enrolled their horses in the study.
The authors would also like to thank Associate professor Dr. Rebecca Langhorn, University of Copenhagen, Denmark for language editing and the Danish Horse Levy Foundation for funding the project.
Funding
The Danish Horse Levy Foundation funded the project but played no role in the design, analysis and reporting of the study.
Author information
Authors and Affiliations
Contributions
All authors have provided substantial contribution to the manuscript. MLH has acquired the sample material, and owner consent, conducted and assisted in data analysis, interpreted results, and have drafted the work and continuously revised it. LNN has made contributions to the design of the work and data interpretation and has revised the work. THP has made contributions to the acquisition and interpretation of data and has revised the work. All authors have read and approved the final manuscript.
Corresponding author
Ethics declarations
Ethics approval and consent to participate
All samples were collected at The Large Animal Teaching Hospital at The University of Copenhagen, Denmark, in 2018. Approval was obtained from the ethical board of the Department of Veterinary Clinical Sciences, University of Copenhagen, as was written consent from the owners of the horses. All procedures were carried out in accordance with the ARRIVE guidelines.
Consent for publication
Not applicable.
Competing interests
The authors declare that they have no competing interests.
Additional information
Publisher’s Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Supplementary Information
Additional file 1:
Table 1s. Heparin dilution curve performed in the calibrated automated thrombin assay. Lag-time, time to peak (ttPeak), peak and endogenous thrombin potential (ETP) are listed. Note that the thrombin potential is completely inhibited at a heparin concentration of 0.037 U/mL. At the lowest concentration of heparin (0.01125 and 0.0225 U/mL), the lag-time and ttPeak are almost identical to 0.0 U/mL, but with a slight 15–20% increase in both Peak and ETP.
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
About this article
Cite this article
Honoré, M.L., Pihl, T.H. & Nielsen, L.N. A pilot study evaluating the Calibrated Automated Thrombogram assay and application of plasma-thromboelastography for detection of hemostatic aberrations in horses with gastrointestinal disease. BMC Vet Res 17, 346 (2021). https://doi.org/10.1186/s12917-021-03058-7
Received:
Accepted:
Published:
DOI: https://doi.org/10.1186/s12917-021-03058-7