Cyclic tensile tests of Shetland pony superficial digital flexor tendons (SDFTs) with an optimized cryo-clamp combined with biplanar high-speed fluoroscopy

Abstract

Background

Long-term cyclic tensile testing with equine palmar/plantar tendons have not yet been performed due to problems in fixing equine tendons securely and loading them cyclically. It is well established that the biomechanical response of tendons varies during cyclic loading over time. The aim of this study was to develop a clamping device that enables repetitive cyclic tensile testing of equine superficial digital flexor tendon for at least 60 loading cycles and for 5 min.

Results

A novel cryo-clamp was developed and built. Healthy and collagenase-treated pony SDFTs were mounted in the custom-made cryo-clamp for the proximal tendon end and a special clamping device for the short pastern bone (os coronale). Simultaneously with tensile testing, we used a biplanar high-speed fluoroscopy system (FluoKin) to track tendon movement. The FluoKin system was additionally validated in precision measurements. During the cyclic tensile tests of the SDFTs, the average maximal force measured was 325 N and 953 N for a length variation of 2 and 4 % respectively. The resulting stress averaged 16 MPa and 48 MPa respectively, while the modulus of elasticity was 828 MPa and 1212 MPa respectively. Length variation of the metacarpal region was, on average, 4.87 % higher after incubation with collagenase. The precision of the FluoKin tracking was 0.0377 mm, defined as the standard deviation of pairwise intermarker distances embedded in rigid bodies. The systems accuracy was 0.0287 mm, which is the difference between the machined and mean measured distance.

Conclusion

In this study, a good performing clamping technique for equine tendons under repetitive cyclic loading conditions is described. The presented cryo-clamps were tested up to 50 min duration and up to the machine maximal capacity of 10 kN. With the possibility of repetitive loading a stabilization of the time-force-curve and changes of hysteresis and creep became obvious after a dozen cycles, which underlines the necessity of repetitive cyclical testing. Furthermore, biplanar high-speed fluoroscopy seems an appropriate and highly precise measurement tool for analysis of tendon behaviour under repetitive load in equine SDFTs.

Background

The superficial digital flexor tendon (SDFT) is one of the most frequently injured structures of the musculoskeletal system in sport horses, particularly in the forelimb [1,2,3,4]. Due to its function, the equine SDFT works close to its physiological limit under maximal load [5]. Loads of up to 14.5 kN [6] and strains of up to 16.6% have been reported during gallop [7].

Long-term cyclic tensile tests have not yet been performed due to insufficient clamping techniques. Riemersma and Schamhardt [8] proposed a cryo-jaw for tensile testing of large animal tendons, which was used and further developed by other investigators [9,10,11,12]. Cryo-jaws have the advantage of holding all tendon fibres equally, without squeezing them, whereas mechanical compressive clamps squeeze the cellular water, which results in slippage [8]. Cryo-clamps have been used to hold equine digital flexor tendons (DFT) during rupture or failure tests [8, 13,14,15,16, 9]. However, during repetitive loading, problems arose including: thawing of the tendon, slipping out of the clamp during cyclic testing [11], breakage of the frozen tendon at the clamp exit. Thus, this limits the possible number of testing cycles. A cyclical loading of equine DFT, up to 3 kN with 30 cycles, was achieved by Swanstrom et al. [17] by fixating the elbow and phalanges with bone pins. Thorpe et al. [15], also with a cryo-clamp, performed 20 loading cycles of up to 4 kN.

In the current study we aimed to develop a clamping device for tendon testing of up to 10 kN and for repetitive tensile testing with at least 60 loading cycles, combining the advantages of former devices. Additionally, we used 3D X-ray motion analysis (fluoroscopic kinematography, FluoKin) to measure the tendon strain of the equine SDFTs via implanted tantalum beads. FluoKin operates as a biplanar, high-speed, fluoroscopic XROMM system [18] with a reported high precision (0.12 ± 0.08 mm and 0.09 ± 0.08° [19]) that can also be used to detect tendon motion [20]. From calculations based on Tashman and Anderst [21], we expected a tendon length variation of about 4 mm to 8 mm during simulated walk and trot.

The presented clamping device was used to reliably analyse healthy and collagenase-injured tendons movement during simulated walk and trot loading. Additionally, precision of the fluoroscopic gait lab was determined to establish high-speed fluoroscopy of the equine SDFT.

Results

Tensile tests

Isolated SDFTs of Shetland ponies, with implanted tantalum beads, were strained in a loading machine and simultaneously video-radiographed with FluoKin. Biplanar video-radiographs with FluoKin were taken within the 60th cycle, when the force to strain the tendon reached a plateau and the tendons were in a preconditioned status (Fig. 1 a). During tensile testing all tantalum beads remained in their position, even after injection of collagenase. A difference in tendon lengths between “walk” and “trot “was significantly detected (p < 0.025) and ranged from about 1.17 cm to 3.83 cm (Fig. 2 a). A difference in tendon lengths could also be shown in the two foal tendons tested in “walk”, “trot”, and “gallop”. Untreated tendons also differed from those injected with collagenase (p < 0.002), ranging from about 3.86 cm to 5.57 cm. There was no significant difference between incubated tendons and those kept at 4 °C overnight (Fig. 2 b).

Fig. 1
figure 1

Loading and unloading patterns of Shetland pony SDFT. a Typical force-time-diagram of repetitive cyclic tensile testing at 4% strain with initial decrease of force and plateau phase., b Stress-time-curves normalized over 1 s, b (I) creep effect in the 1st cycle at 2 and 4% strain, b (II) creep effect in the 1st cycle at 6% strain in untreated SDFT (blue) and with collagenase (orange) during the 60th cycle, b (III) creep effect during the 1st to 60th cycle in untreated SDFT at 6% strain, c Hysteresis curves during “walk” (black) vs. “trot” (red) during the 60th cycle, d Hysteresis curves in untreated SDFT (blue) and with collagenase (orange) during the 60th cycle, e Hysteresis curves at 4% strain (“trot”) during the 1st to 10th cycle and at 6% strain during the 60th to 90th cycle in untreated SDFT

Fig. 2
figure 2

Measuring strain of the SDFT with FluoKin. Measuring strain within the 60th loading/unloading cycle on the basis of changing intermarker distances of implanted tantalum beads in the SDFT detected with FluoKin. a Spatial displacement of the proximal and distal tantalum bead at walk (black) and trot (red), b Mean difference between two tantalum beads during load cycles mimicking different gaits (error bars reflecting its maximum and minimum), dark grey: “gallop”, white: “walk”, grey: “trot”

To lengthen the SDFTs by 2%, 325 N were necessary on average, whereas 953 N were required to achieve a lengthening of 4%. Thus, an average stress of 16 MPa and 48 MPa, and an average modulus of elasticity of 828 MPa and 1212 MPa, resulted respectively for 2 and 4% lengthening (Table 1). The tendon strain and modulus of elasticity were reproducible after 30 min of rest.

Table 1 Mechanical properties of the SDFTs of mature Shetland ponies (data from 21 measurements)

When plotting the data of stress and strain at the 60th test cycle, continuously over time, the relaxation curve is lower than the loading curve. This phenomenon is called hysteresis. Simulating “trot” we found a pronounced cushioning effect, whereas this effect was very low when simulating “walk” (Fig. 1 c). After injection of collagenase the hysteresis curve rose much slower and the area between the loading and relaxing curve is decreased by 17.2 -55.2% (Fig. 1 d). The hysteresis curves of the 60th to 90th loading cycle were almost completely congruent (Fig. 1 e).

During the short holding phase with constant strain of each cycle, when the tendon is loaded, the stress [MPa] decreased significantly at 2% strain (“walk”) 0.029 ± 0.008%, at 4% strain (“trot”) 0.048 ± 0.018%, and at 6% strain (“gallop”) without collagenase 0.086 ± 0.004%, and with collagenase 0.121 ± 0.013% (Fig. 1 b). This phenomenon describes the “creep”. The effect of creep was more pronounced in the early loading cycles and attenuated steadily (Fig. 1 b).

To test the capacity of the clamps to hold the tendon, a repeated cyclic loading with at least 50 min duration at 1.5 kN was carried out with the cryo-clamps for Shetland pony SDFT. Additionally, failure test until rupture were carried out. No slippage of the tendon was observable or other signs of failure (Fig. 1 a and Additional file 2).

Precision measurements of the FluoKin system

To determine accuracy and precision of the FluoKin lab an aluminium sheet with embedded beads was imaged in a static position and by dynamically waving it through the image field (Fig. 3 a and c, Table 2). The mean measured distance between all bead pairs differed significantly between the static and dynamic measurement (p < 0.0001).

Fig. 3
figure 3

Measuring precision of the FluoKin gait lab. a Test sheet (70 mm × 60 mm × 4 mm to 2 mm falling edge from the largest to the smallest beads, front view (with imprinted distance [mm] for each pair of beads) and side view), b Resolution of the FluoKin system, images of the two image intensifier/camera systems without magnification, c Precision measurements with tantalum beads (0.8 mm and 1.0 mm) in an aluminium sheet and a forelimb (tendon and bone); *significant difference (p < 0.019)

Table 2 Characteristics of precision and accuracy of the FluoKin gait lab. Static (stat) and dynamic (dyn) measurements with implanted beads in an aluminium sheet (mean values)

The 0.8 mm and 1.0 mm tantalum beads were also implanted in the SDFT and metacarpal bone respectively, of a forelimb. The limb was then frozen to prevent any marker movement during static and dynamic measurements (Table 3).

Table 3 Precision of the FluoKin gait lab measured with implanted beads in a frozen forelimb

Spatial resolution of the FluoKin system (including the two image intensifiers, lens system, and high-speed cameras) was 1.2 lp/mm and 1.0 lp/mm in standard mode, 1.8 lp/mm and 1.4 lp/mm in magnification mode 1, and 2.2 lp/mm and 2.0 lp/mm in magnification mode 2 (Fig. 3 b).

Discussion

In the present study, we developed a good working cryo-clamp for prolonged repetitive cyclic tensile testing with equine SDFT. This surpasses the previous problems in fixing equine tendons securely during cyclic testing. The results of our tensile testing with Shetland pony SDFTs suggests that measuring biomechanical properties should be undertaken in properly preconditioned tendon tissue when the plateau phase is reached. Additionally, length variation of moving tendons was recorded with FluoKin, a biplanar X-ray analysis system, through tracking position changes of implanted tantalum beads. Furthermore, the precision of the FluoKin system was assessed. We will now provide a detailed description of the clamp, discuss the results of the tensile testing, and end with discussion about the precision testing.

An optimized cryo-clamp for equine tendons

In 1982, Riemersma and Schamhardt proposed a cryo-jaw for testing equine digital flexor tendons. This design has been modified over the years [9, 22,23,24,25]. Long-term cyclic tensile tests have not been performed so far due to problems such as thawing of the tendon and slipping out of the clamp [11]. As Fig. 1 a shows, there is a drop in the required force, especially in the first loading cycles. Therefore, it is recommended to take measurements only after the force-time curve has stabilized and the tendon is in a preconditioned status. As part of the work presented here, we designed and built a cryo-jaw for prolonged cyclic tensile tests that avoids slippage, damage, or disruption of the tendon (Fig. 4 c).

Fig. 4
figure 4

Mounting and cryogenic clamping devices for cyclic testing with pony SDFT. a mounting device for the short pastern bone (os coronale) with b technical drawing including a schematic of the specimen, c cryo-clamp, opened and with copper filling tube, d SDFT in the cryo-clamp mounted in the u-shaped connector, e technical drawing of one cryo-jaw, side view, f technical drawing of one cryo-jaw, top view

The hollow cryo-clamps were filled with liquid nitrogen. Vents in each clamping jaw prevented pressure from building up. The filling tubes were made of copper, making it easy to curve and process them. Rubber ring seals prevented the filling tubes of slipping out of the clamp. The funnels for filling the liquid nitrogen into the copper tubes were made of Teflon, a synthetic material that is resistant to − 200 °C. Freezing the tendon on the clamp by cooling it with liquid nitrogen attached all tendon fibres equally to the clamp. It seemed essential, for repetitive cyclic testing, to keep the clamp cold continuously. Otherwise, slippage is likely above 3.5 kN [8]. A wave profile increased the contact surface providing a large freezing area. The clamp profile was adapted to the thickness of pony SDFTs. Its outline enabled closure of the clamping jaws without shear forces occurring, because of an even distance between the two profiles at every distance of the two clamping jaws. We recommend using a clamp profile adapted to the tendon’s diameter to completely freeze and securely hold it. In this way, the freezing and special wave profile ensured that all tendon fibres are included in the loading during tensile tests which imitated physiological conditions more closely. Unlike mechanical clamps, there are no artefacts due to squeezing. To prevent any disruption of the deep-frozen tendon at the edges of the clamps, where the tissue exited, were radiused at 2 mm and the clamps offset from one another by 10°.

Breakage of the tendon tissue above the clamps or slippage out of clamp did not occur at 10 kN, which was the maximum capacity of the testing machine. This quality feature of the cryo-clamps would also allow the performance of yield and rupture tests (see Additional file 2). With Shetland pony SDFTs, up to 50 min cyclic tensile testing with 1.5 kN was performed without tendon slippage out of the clamp. At that point, the liquid nitrogen stock was used up. Experiments with longer duration and higher loads are feasible. Nevertheless, to ensure proper testing, storing the clamps at − 80 °C overnight prior to the experiment is recommended. Additional cooling by a sleeve with dry ice around the cryo-clamps could reduce the consumption of liquid nitrogen. Aluminium, as a clamping material, ensures a high thermal conductivity and sufficient resistance. The clamps surface that was in contact with the tendon was roughened for an optimal temperature transfer. We measured the temperature gradient along the fixated tendon with an infrared thermometer. We measured − 7 °C on the tendon surface next to the cryo-clamp. The surface of the tendon tissue of all specimens reached room temperature at the longest 3 cm away from the frozen clamp. Similar cryo-clamps have required a safety distance of 5–6 cm from the cryo-clamps to the measuring zone [8, 14, 16]. In order to avoid cold artefacts within the measuring zone the entire length of the tendon should be used.

The cryo-clamp described here may not be appropriate to perform repetitive cyclic tensile tests with tendons containing a larger diameter than the SDFTs of ponies. To test the SDFTs of horses or the DDFTs of ponies, which have larger diameter tendons, we built another cryo-clamp with a larger clamping profile (Fig. 5). Its cooling chamber is also more spacious, because the clamp as a whole is larger. To create a larger imaging field in FluoKin, the filling tubes of the larger clamp enter frontally. This enables an automatic tracking of the tantalum beads implanted in the tendons. Also, the tendon was strained with a previously unreached repetitively applied, tensile force of 9500 N. This was limited not by the cryo-clamp itself but rather by the maximum force of the machine (10 kN).

Fig. 5
figure 5

Cryogenic clamping device for pony DDFT or SDFT of horses (30 × 55 × 80 mm). a Front view with copper filling tube, b Inside front view, c Front view with coated filling tube and Teflon funnel. We used a custom foam pipe insulation to keep the clamping device cold for a noticeably longer time

The proximal end of the SDFTs were fixated in the cryo-clamp, whereas to hold the distal end of the SDFTs, the enthesis of the short pastern bone (os coronale) was used. Using the attached bone to hold the tendon provided advantages for occupational safety. More specifically, no liquid nitrogen cooled cryo-clamp was needed at the moving transverse of the tensile testing machine. During the tensile tests, the curved shape of the bearing pin distributed the force at the articular surface of the os coronale better than a simple rod shape. During tensile stress, force is also built up on the os coronale via the palmar adjusting gate. To minimize force peaks and to enlarge the contact area, the adjusting gate was placed at the height of an anatomical indentation at the palmar aspect of the os coronale.

Though the SDFT undergoes tensile loading throughout the whole stance phase, the peak load occurs in the early stance phase [26]. The device imitated the physiological position of the os coronale when the leg stands vertically through an angulation of 55°. Additionally, the position of the os coronale could be fixed with two adjusting gates, which are in grooves and shifted via wheel screws. We imitated the gliding surface of the scutum proximale with a rotatable cylinder. Consequently, during tensile testing, the tendon fibres were loaded in their physiological force direction of the main load phase. The parts of the device were screwed together, rather than welded, for better force resistance. The stainless steel used provided corrosion resistance.

A limitation of the mounting device was its fixed angles. To better imitate a step, a tiltable device would be beneficial. To also test the SDFTs of horses, the device would need to be larger. Also, a slidable pulley would allow for a more suitable adjustment. For repetitive cyclic tensile testing we recommend using this proposed novel mounting device for the bone, with the tendon’s enthesis, in order to avoid the need for a second cryo-clamp. Additionally, the tendon fibers can be loaded in their natural direction.

Tensile tests

To test the new cryo-clamp Shetland pony SDFTs were subjected to repetitive cyclic tensile testing and failure tests until rupture. The tensile testing protocol contained loading, loaded, unloading and unloaded phases with strain and time dependent on the imitated “gait”. We decided to use 2, 4 and 6% for “walk”, “trot” and “gallop” respectively. These values were estimated for the body weight of Shetland ponies based on Riemersma et al. [21] who found a lengthening in vivo of 2.13–2.19% during walk and 3.99–4.15% during trot in the SDFTs of Icelandic ponies. In horses, Butcher et al. [1] reported 3.6% at walk, 5.6% at trot, and 4.8% at canter, also in the SDFTs. Those values seem to be dependent on the gait velocity, e.g. Lawson et al. [27] found 6.7% at walk and 8.5% at trot. Strain of the SDFTs of Shetland ponies in vivo still needs to be determined and related research is underway.

For more reproducible measurements, it is recommended to precondition the tendon by loading it 10 to 30 times prior to measuring [28,29,30]. Preconditioning implies a reversible change of the microstructural response to strain [31] such as lengthening of the fibres [32] through straightening of the fibre’s crimp and squeezing out the procollagen water mixture [33,34,35, 31]. Video-radiographs in our study were taken during the 60th cycle to ensure we measured within the plateau phase of the force straining the tendon. Dakin et al. [10] tested several repetitions after a single cycle of preconditioning. They strained the SDFTs up to 5% with 0.5 Hz. Swanstrom et al. [17] tested equine DFT 30 times with 1 Hz for 400 N to 3000 N after 5 cycles of preconditioning. Thorpe et al. [36] described tensile tests of the equine SDFTs up to 4 kN with 20 repetitive cycles. To the authors best knowledge there have not been any other prolonged cyclic tensile tests with equine SDFTs to date.

In the current study with Shetland pony SDFTs, 325 N and 953 N on average were required on average to lengthen the specimens of 2 and 4% respectively. In pony tendons 2.2–5.5 N/kg at walk and 6.3–7.0 N/kg at trot were measured in vivo [26, 37, 38, 21]. We used tendons of Shetland ponies (estimated body mass of about 130–180 kg) in our study which would result in a force of 1.05–1.45 N/kg at “walk” and 7.2–10.0 N/kg at “trot”. Measured in horses in vivo, the average maximum force has been reported to be 3.1–3.8 kN at walk, 4.7–6.0 kN at trot and 5.1–7.0 kN at canter [39]. Ex vivo, maximum forces in horses ranged between 6.7–14.5 kN [13, 6, 40, 11, 14, 15].

Stress, measured in the present study with Shetland pony tendons, was higher (11–61 MPa) than measured previously in horses (45.7–71.8 MPa [1, 13, 11];), due to their smaller cross-sectional area (0.21 ± 0.04 cm2). For Shetland ponies, the elastic modulus in our study was between 551 and 1523 MPa. Elastic modulus ex vivo has been suggested to vary between 740 and 1408 MPa in horses [13, 6, 40, 17, 15].

Plotting the loading and unloading curves of “walk” and “trot” hysteresis is obvious (Fig. 1 c). Hysteresis refers to an energy dissipation due to viscoelastic properties and is described by the area and distance between the two curves [41]. Hysteresis correlates with the absorption of energy [41] and the scope of the cushioning effect [42]. During “trot” the tendon undergoes higher stress than during “walk” and more hysteresis can be seen (Fig. 1 c). Simulating “trot” forces the tendon fibres to strain more viscoelastically, rather than elastically. The higher the utilization of elastic energy the lower is the hysteresis [43,44,45]. In contrast to our ex vivo simulations of “walk” and “trot”, hysteresis was minimized at high strain rates [46] in order to optimize energy efficient locomotion in vivo. The hysteresis effect reached a constant phase between the 60th and 90th loading cycle indicating that the tendon tissue is in a preconditioned status (Fig. 1 e).

During the short holding phase with constant strain, within each cycle a significant decrease of stress was detected (Fig. 1 b). This phenomenon is called “creep” or “cold flow”. Simulating trot, this decrease was significantly more pronounced than at walk (p = 0.018). During 6% strain, the stress decreased significantly more in the collagenase-treated tendons than in those without collagenase (p = 0.034). The creep occurred mainly in the first third of the holding phase (Fig. 1 b). During this phase, energy stored within the tendon is released, which is advantageous for absorbing vibrations [42]. This viscoelastic behaviour of the SDFT is one of its cushioning mechanisms. The effect of creep attenuated as the number of loading cycles increased (Fig. 1 b III), which is also a sign that the tendon tissue has reached a preconditioned status.

In collagenase-treated tendons Nabeshima et al. [47] found a decrease of stiffness, maximum failure force, and both elongation and energy to maximum force. Crevier-Denoix et al. [40] compared healthy and injured tendons and found a decrease of maximum load of 1.4 kN and maximal stress of 71.3 MPa, on average. Our results are in accordance with those of Crevier-Denoix et al. [6] who also needed higher force to strain injured tendons. Length variation measured with FluoKin was on average 4.87% higher in specimens treated with collagenase than without (Fig. 2 b). The massive changes in the biomechanical properties of the SDFTs after injection of collagenase can also be seen in the hysteresis curve. Figure 1 d shows this as less uptake of stress, a smaller area between the curves, and as a higher creep (Fig. 1 b). Collagenase-induced degradation of the tendon tissue and structure of the collagen network (e.g. [48, 49]) likely leads to the changes of the tendon’s biomechanical response. The destruction of collagen fibres by collagenase leads to less resistance to tensile force, less absorption of energy and to a decrease of the cushioning effect. The interaction of the collagen fibres in processes such as interfibrillary cross-linking or electrostatic attraction [50, 51] is disturbed through the disruption of their structural properties.

Using a Clostridium histolyticum derived collagenase is common to initiate a tendon lesion [52,53,54,55, 47] but limits our conclusions because of its multiple action sites along the collagen triple-helix compared to mammalian collagenase, which reacts only at a single site [48, 56]. Additionally, ex vivo testing lacks the inflammatory response and a functioning cell-to-cell-communication. Nevertheless, our results show that collagenase treatment of equine SDFTs ex vivo was able to influence the biomechanical response to strain and provide useful information for in vivo experiments.

The present study focused on the forelimb SDFTs of the Shetland pony. Its energy storing ability depends on the gait speed, with stress increasing with speed, whereas this ability remains more constant in the hindlimb [57]. Riemersma and Schamhardt [58] found an elastic modulus of 1000–1282 MPa in the hindlimb SDFTs. The hindlimb’s functional specialization could lead to different mechanical characteristics of its SDFTs.

Differences in the biomechanical behaviour of the tendons between pony and horse are possible. A pony’s hoof is relatively small with high heels and a short toe. Additionally, the propulsion phase during stance is less ample compared to horses [59]. Deviation due to sex, age, race, training, ground surface, anatomical site, and method of measurement and its precision are also known to affect the tendon’s biomechanical response. A difference in age and sex of the donor animals might also be a reason for the relative broad ranges of maximum force, stress, and modulus of elasticity in Table 1.

Age-dependent changes in biomechanical behaviour of tendons due to morphological and biochemical changes have been widely studied [60,61,62,63,64,65,66]. We did not notice any significant age-related influence on our results (with the exception of the two specimens derived from foals). Some studies in humans report a decrease of tendon stiffness with age [67, 68], while others report an increase [69]. Addis and Lawson [60] found an increase of strain with age. Thorpe et al. [65] found no influence of age on elastic modulus, failure stress, or strain of the whole SDFTs, but a significantly less fascicle sliding in aged tendons.

In the current study, load-dependent length variation in the SDFTs was detected for the first time with biplanar high-speed fluoroscopy. During the experiments the position of the implanted tantalum beads remained stable. As Smith et al. [70] commented, it is important to inject the beads across the grain to prevent bead migration along the injection canal in the tensile direction. One way to overcome this problem is also to drill a hole in the bead and suture it to the tissue [71] or to close the injection hole with fibrin glue [72, 73]. In vivo, tantalum is bio-inert [74] and can be used in long-term studies without tissue reaction.

We focused on the metacarpal region of the SDFTs, nevertheless it is also possible to video-radiograph the whole tendon with FluoKin. However, due to the narrow field of biplanar measurement (approximatively 6000 cm2) the image sequences must be assembled from different heights depending of the length of the specimen. The detection method, using implanted tantalum beads, could also be employed on other structures, e. g. on the deep digital flexor tendon (DDFT). It is advisable to inject the markers from lateral or medial in the DDFT and not from palmar/plantar in proximodistal direction as conducted in this study.

Precision measurements of the FluoKin system

In the current study, FluoKin, a 3D X-ray motion analysis system, was used to measure the length variation between tantalum beads implanted in the SDFT. Additionally, the precision of the FluoKin system was assessed by measuring the intermarker distance between radiopaque markers embedded in rigid bodies. The results provide not only the precision estimations for this study, but also for our FluoKin gait lab in general.

To measure precision of the Leipzig FluoKin gait lab, we used an aluminium sheet and a frozen distal forelimb with embedded markers which should remain in a stable position within rigid bodies [20]. To assess the accuracy of the system, a test object with a known distance between the markers is required [20]. In our study, all distances in the sheet measured with FluoKin differ significantly to the machined distance. Nevertheless, a qualitative conclusion cannot be drawn, because measurements taken with one technique are related among themselves, since they contain the same bias. Under optimal conditions, the Leipzig FluoKin gait lab can assess an accuracy of 0.0287 mm, a precision of 0.0377 mm and a range of 0.2348 mm. These values are in the same range as data from the Keck Foundation XROMM Facility at Brown University (precision of 0.046 mm, 18) and the 3D2YMOX system at the University of Antwerp (precision of 0.066 mm, range of 0.236 mm, [75]).

The quality of marker tracking depends on the diameter of the markers and the contrast to the surrounding material and can be reached under static conditions. Dynamic measurements are generally more imprecise than static ones due to the inevitable motion blur. X-ray permeability of tendon tissue is better than the more radiopaque bone tissue. It seems that beads with larger diameter are tracked more precisely (with lower standard deviation), but the accuracy of smaller beads more circumscribed in the X-ray image could not be reached. This study compares for the first time precision parameters of 5 different marker sizes within one FluoKin video. The highest precision was obtained using 0.8 mm beads in tendon tissue under static conditions (0.0144 mm). Whereas the most imprecise measurement occurred with 1.0 mm beads in bone tissue under dynamic conditions (0.0985 mm). In praxis, the choice of the bead diameter is often a compromise between precision parameters and enough contrast to the surrounding tissue. Additionally, to optimize contrast, the voltage of the X-ray tube can be suited to the k-absorption edge of the marker material [76], 90 kV should be chosen for tantalum [18]. The energy used should be a compromise between the best tantalum and tissue contrast. Software used for marker tracking evolves quickly and surely improves in terms of precision.

The main causes of imprecision are technical artefacts during image processing. To maximise precision all components from the X-ray hardware to the analysing software should be perfectly compatible with each other. For example, a loss of precision could be caused by one of the image intensifiers not producing an image of equal sharpness as the other, possibly due to its age. Image intensifiers convert the X-ray radiation into a visible and brightened light image. The spatial resolution of image intensifiers is typically about 4 lp/mm. We reached 1.0 to 2.2 lp/mm in standard and magnification mode. According to Brainerd et al. [18], the limitation in the image chain is the 1024 × 1024 pixels resolution of the high-speed cameras. Overall, our image quality, in terms of resolution, is comparable to that reported by Brainerd et al. [18] (1.5 lp/mm without magnification and 2.2 lp/mm with magnification) and Sanctorum et al. [75] (2.2 lp/mm and 2.5 lp/mm without magnification for the two image intensifiers and 3.4 lp/mm for magnification 1 and 4.6 lp/mm for magnification 2). Sanctorum et al. [75] used 4 megapixel cameras and recommend upgrading older systems to increase the resolution.

Conclusion

We present an optimized, inexpensive, custom-made clamping technique that allows prolonged cyclic measurements of equine tendons. Repetitive cyclic testing of up to 50 min at 1.5 kN with Shetland pony SDFTs was successfully performed. Common problems such as tendon damage, disruption, or slipping did not occur. It was not necessary to suture or mechanically clamp the tendons. Loading of up to 10 kN was performed, which was not necessarily a physiological limit but the limit of the testing machine. Filling the clamp with liquid nitrogen via funnels enables repetitive cyclic measurements. Due to this cooling procedure and the mentioned technical adjustments of the clamp’s design, prolonged cyclic tensile testing was possible without any slippage or breaking of the tendon. We tested equine tendons, without ceasing, for up to 50 min, which represents a new precedent in tensile testing.

Tendon strain in motion was recorded with FluoKin by assessing changes of intermarker distances of implanted tantalum beads. Such a setup opens the way to monitor the segmental strain behaviour of tendons in long-term in vivo studies. The precision of bead tracking with videos derived from the FluoKin gait lab covers a range of ±0.1 mm (Tables 2 and 3). The precision of bead tracking in moving tendon tissue was 0.0553 mm — adding weight to our tensile results.

FluoKin is a useful experimental tool to assess the elasticity of insulted or healing tendons and to observe correlates of therapy success. Nevertheless, future in vivo investigations regarding tendon strain under different conditions, using FluoKin, are required and underway.

Methods

Specimens

From Shetland pony forelimbs, 17 SDFTs including the short pastern bone (os coronale) were dissected. These ponies had died of natural causes or were euthanized for medical reasons not related to this study. The forelimbs were provided after the veterinary post mortem examination. The maximum time of storage at − 20 °C before testing was 9 months. All specimens were examined with ultrasound (MyLabTwice, Esaote Biomedica Deutschland GmbH, Köln, Germany) to ensure only healthy tendons were tested. None of the specimens were discovered to be compromised. Additionally, the tendon diameter was measured (GE Healthcare, scil animal care company GmbH, Viernheim, Germany). Throughout all examination procedures the tendons were kept moist with isotonic saline solution. The dissected tendons were stored in double plastic bags at − 20 °C for a maximum of 16 days before testing and then thawed at 4 °C prior to the testing. To visualize the tendon’s length variation with FluoKin, 8 spherical tantalum beads (diameter of 0.8 mm, X-medics, Scandinavia, Frederiksberg, Denmark) were implanted into each tendon using an 18 G cannula and a custom-made mandrel controlled by ultrasound. Four beads were placed along the longitudinal axis in the tendon centre and supplemented with an additional spare bead at each level.

Test protocol

The tensile tests were performed with a Zwick Z 010® testing machine and its loading cell (< 10 kN) (ZwickRoell GmbH & Co. KG, Ulm, Germany). The speed of the machine was 1500 mm/min. Ten specimens were loaded with 2 and 4% strain to respectively simulate walk and trot ex vivo (Fig. 6). This was performed again with specimens which were stored at 4 °C overnight (referred to as the “4 °C” group) and incubated at 37 °C for 12 h (“incubated” group). Two tendons from foals were loaded additionally with 6% strain (“foals” group). Four specimens received a 6% strain (“without collagenase” group) and were injected afterwards with 0.1 ml HBSS (Hank’s Balanced Salt Solution) and collagenase I (Life Technologies GmbH, Darmstadt, Germany, catalogue number 17100017) at a concentration of 4.8 mg/ml and incubated at 37 °C for 12 h (“with collagenase” group). Four additional specimens served as controls for the collagenase-treated group, also being incubated (control group “incubated”). For walk and trot respectively, in all conditions, strain was held for 0.2 s and 0.08 s (loaded holding phase) with an interval of 0.38 s and 0.24 s of rest between the loading cycles (unloaded phase). The specimens were continuously loaded with 70 loading/unloading cycles for up to 5 min and additionally video-radiographed with biplanar, high-speed, fluoroscopy after 60 loading cycles. Additionally, test protocols with 125 and 200 loading/unloading cycles or until tendon rupture were also carried out.

Fig. 6
figure 6

Schematic design for the testing protocol of each group

Fixation device

The short pastern bone (os coronale) was mounted in a stainless-steel device that was screwed onto the loading machine via a 10 mm base plate (Fig. 4 a and b). The short pastern bone rested with its proximal articular surface on a bearing pin, where its curvature imitated the distal articular surface of the os coronale. Additionally, two adjusting gates with wheel screws held the bone in its position (Fig. 4 a and b). The SDFT was led across a rotatable pulley of 50 mm diameter to imitate the scutum proximale. The center-to-center distance of the bearing pin to the pulley was 67 mm. Due to their relative position to each other, the short pastern bone was mounted at an angle of approximately 50–55°.

The proximal end of the SDFT was fixed in a custom-designed cryogenic clamp made of aluminium (Fig. 4 c and d). The jaws were filled with liquid nitrogen via copper tubes and Teflon funnels. To achieve optimal cooling the clamping device was stored at − 80 °C overnight. From one solid piece, the two clamping jaws were cut apart in an optimized wave profile which allowed the converging of the jaws without creating shear forces. This occurs because at each distance of the jaws from one another, the space between the crest and trough of the wave is the same along the profile. At the upper and lower edges, the wave profile opens up by 10° and the edges are rounded with a radius of 2 mm to prevent disruption of the deep-frozen tendon. The 2.5 mm distance between wave crests was specifically adopted for pony SDFTs. Two holes were drilled vertically in each of the jaws, which were expanded with three horizontal recesses to enlarge the cooling surface (Fig. 4 e and d). One hole of each jaw was closed with a threaded plug with vent hole that could be opened if needed. The other hole was coated with rubber to hold the filling tube. The cryo-jaws were mounted to the testing machine with a u-shaped connector (Fig. 4 d).

Biplanar high-speed fluoroscopy

FluoKin is as a 3D X-ray motion analysis system with biplanar arranged fluoroscopic units, which are retrofitted with high-speed cameras. A moving object is video-radiographed continuously for 6 s from two directions. This enables the reconstruction of its movements in three-dimensional space. To measure the length variation of soft tissue it is necessary to implant radiopaque markers, e.g. tantalum beads. The fluoroscopic examinations of the present study were performed at the FluoKin gait lab of Leipzig University, which is further described in Weiss et al. [77] and Geiger et al. [78]. Specimens were imaged at 46–50 kV and 80 mA, with 0.5 s shutter speed, without magnification, a source to image distance of 140 cm, and an interbeam angle of approximately 60° simulating an in vivo experimental set-up. Videos were recorded during the 60th testing cycle, at a resolution of 1024 × 1024 pixels, and at 200 fps. A sample video file showing the recording of one of the two high-speed cameras (during testing) can be found as Additional file 1. Undistortion, calibration, and marker tracking were performed with XMALab (version 1.3.8, www.bitbucket.org/xromm/xmalab, download 30-Sept 2016) according to Knoerlein et al. [79]. The tracked beads were manually adjusted after running an automatic marker tracking procedure as well as a polynomial fitting technique. The mean reprojection error was 0.2454 pixels. Data were filtered with a low-pass, 5th order Butterworth filter at 35 Hz.

Precision measurements of the FluoKin system

Precision and accuracy were measured with A) pairs of steel and tantalum beads embedded, with a known distance, in an aluminium sheet (“sheet”) and B) tantalum beads implanted in a frozen distal pony forelimb. In a frozen object, intermarker distances should, ideally, not differ from frame to frame. Both test objects (A and B) were video-radiographed at 500 fps in a biplanar set-up of the gait lab. The imaging parameters deviated from those described above. The aluminium sheet was imaged at 50 and 55 kV and 100 mA, while the frozen distal forelimb was imaged with 55 and 63 kV and 100 mA. This ensured a satisfactory image quality. In the aluminium sheet, several kinds of beads had been embedded that are often used in our gait lab: 5 mm and 3 mm steel beads, 1.6 mm, 1 mm, and 0.8 mm tantalum beads. The distances of the embedded beads were determined via X-ray microtomography (Bruker Skyscan 1172–100-50). For the distal forelimb, five tantalum beads (diameter of 1.0 mm) were implanted into the metacarpal bone as widely distributed as possible while avoiding linearity. Four tantalum beads (diameter of 0.8 mm) were implanted into the SDFT. Both test objects were then video-radiographed statically (1976 frames of the sheet, 5473 frames of the forelimb) and dynamically by waving the sheet (2816 frames) and simulating a stepping motion with the forelimb attached to a wooden pole (5021 frames). Precision parameters were calculated as described by Brainerd et al. [18]. Additionally, the interior angles of all triangles between each combination of three bone or tendon beads, implanted in the frozen forelimb, were determined. There was no filtering of the data. Resolution of the FluoKin system was measured by imaging an X-ray test pattern. Statistical examination was carried out with t-tests using the RStudio software (RStudio Inc., Boston, Massachusetts, USA). Results were considered to be significant when p < 0.05.

Availability of data and materials

The datasets used and analysed during the current study are available from the corresponding author on reasonable request.

Abbreviations

DDFT:

Deep digital flexor tendon

FluoKin:

Fluoroscopic kinematography, the 3 D X-ray motion analysis system at Leipzig University

SDFT:

Superficial digital flexor tendon

DFT:

Digital flexor tendons

References

  1. Butcher MT, Hermanson JW, Ducharme NG, Mitchell LM, Soderholm LV, Bertram JEA. Superficial digital flexor tendon lesions in racehorses as a sequela to muscle fatigue: a preliminary study. Equine Vet J. 2007;39(6):540–5. https://doi.org/10.2746/042516407X212475.

    Article  CAS  PubMed  Google Scholar 

  2. Kasashima Y, Takahashi T, Smith RKW, Goodship AE, Kuwano A, Ueno T, et al. Prevalence of superficial digital flexor tendonitis and suspensory desmitis in Japanese thoroughbred flat racehorses in 1999. Equine Vet J. 2004;36:346–50.

    Article  CAS  Google Scholar 

  3. Patterson-Kane JC, Firth EC. The pathobiology of exercise-induced superficial digital flexor tendon injury in thoroughbred racehorses. Vet J. 2009;181(2):79–89. https://doi.org/10.1016/j.tvjl.2008.02.009.

    Article  PubMed  Google Scholar 

  4. Williams RB, Harkins LS, Hammond CJ, Wood JL. Racehorse injuries, clinical problems and fatalities recorded on British racecourses from flat racing and National Hunt racing during 1996, 1997 and 1998. Equine Vet J. 2001;33(5):478–86. https://doi.org/10.2746/042516401776254808.

    Article  CAS  PubMed  Google Scholar 

  5. Dowling BA, Dart AJ. Mechanical and functional properties of the equine superficial digital flexor tendon. Vet J. 2005;170(2):184–92. https://doi.org/10.1016/j.tvjl.2004.03.021.

    Article  CAS  PubMed  Google Scholar 

  6. Crevier-Denoix N, Collobert C, Pourcelot P, Denoix JM, Sanaa M, Geiger D, et al. Mechanical properties of pathological equine superficial digital flexor tendons. Equine Vet J Suppl. 1997:23–6.

  7. Stephens PR, Nunamaker DM, Butterweck DM. Application of a hall-effect transducer for measurement of tendon strains in horses. Am J Vet Res. 1989;50(7):1089–95.

    CAS  PubMed  Google Scholar 

  8. Riemersma DJ, Schamhardt HC. The cryo-jaw, a clamp designed for in vitro rheology studies of horse digital flexor tendons. J Biomech. 1982;15(8):619–20. https://doi.org/10.1016/0021-9290(82)90073-2.

    Article  Google Scholar 

  9. Bowser JE, Elder SH, Rashmir-Raven AM, Swiderski CE. A cryogenic clamping technique that facilitates ultimate tensile strength determinations in tendons and ligaments. Vet Comp Orthop Traumatol. 2011;24(05):370–3. https://doi.org/10.3415/VCOT-10-09-0128.

    Article  CAS  PubMed  Google Scholar 

  10. Dakin SG, Jespers K, Warner S, O'Hara LK, Dudhia J, Goodship AE, et al. The relationship between in vivo limb and in vitro tendon mechanics after injury: a potential novel clinical tool for monitoring tendon repair. Equine Vet J. 2011;43(4):418–23. https://doi.org/10.1111/j.2042-3306.2010.00303.x.

    Article  CAS  PubMed  Google Scholar 

  11. Dowling BA, Dart AJ, Hodgson DR, Rose RJ, Walsh WR. Recombinant equine growth hormone does not affect the in vitro biomechanical properties of equine superficial digital flexor tendon. Vet Surg. 2002;31(4):325–30. https://doi.org/10.1053/jvet.2002.33591.

    Article  PubMed  Google Scholar 

  12. Everett E, Barrett JG, Morelli J, DeVita R. Biomechanical testing of a novel suture pattern for repair of equine tendon lacerations. Vet Surg. 2012;41:278–85. https://doi.org/10.1111/j.1532-950X.2011.00905.x.

    Article  PubMed  Google Scholar 

  13. Crevier N, Pourcelot P, Denoix JM, Geiger D, Bortolussi C, Ribot X, et al. Segmental variations of in vitro mechanical properties in equine superficial digital flexor tendons. Am J Vet Res. 1996;57(8):1111–7.

    CAS  PubMed  Google Scholar 

  14. Gerard MP, Hodgson DR, Rose RJ, Walsh WR. Effects of recombinant equine growth hormone on in vitro biomechanical properties of the superficial digital flexor tendon of Standardbred yearlings in training. Vet Surg. 2005;34(3):253–9. https://doi.org/10.1111/j.1532-950X.2005.00038.x.

    Article  PubMed  Google Scholar 

  15. Thorpe CT, Stark R. J F, Goodship AE, Birch HL. Mechanical properties of the equine superficial digital flexor tendon relate to specific collagen cross-link levels. Equine Vet J Suppl. 2010;42:538–43. https://doi.org/10.1111/j.2042-3306.2010.00175.x.

    Article  Google Scholar 

  16. Vergari C, Pourcelot P, Holden L, Ravary-Plumioën B, Laugier P, Mitton D, et al. A linear laser scanner to measure cross-sectional shape and area of biological specimens during mechanical testing. J Biomech Eng. 2010;132(10):105001. https://doi.org/10.1115/1.4002374.

    Article  PubMed  Google Scholar 

  17. Swanstrom MD, Stover SM, Hubbard M, Hawkins DA. Determination of passive mechanical properties of the superficial and deep digital flexor muscle-ligament-tendon complexes in the forelimbs of horses. Am J Vet Res. 2004;65(2):188–97. https://doi.org/10.2460/ajvr.2004.65.188.

    Article  PubMed  Google Scholar 

  18. Brainerd EL, Baier DB, Gatesy SM, Hedrick TL, Metzger KA, Gilbert SL, Crisco JJ. X-ray reconstruction of moving morphology (XROMM): precision, accuracy and applications in comparative biomechanics research. J. Exp. Zool. 2010;9999A:n/a. doi:https://doi.org/10.1002/jez.589.

  19. Miranda DL, Schwartz JB, Loomis AC, Brainerd EL, Fleming BC, Crisco JJ. Static and dynamic error of a biplanar videoradiography system using marker-based and markerless tracking techniques. J Biomech Eng. 2011;133(12):121002. https://doi.org/10.1115/1.4005471.

    Article  PubMed  PubMed Central  Google Scholar 

  20. Tashman S, Anderst W. In-vivo measurement of dynamic joint motion using high speed biplane radiography and CT: application to canine ACL deficiency. J Biomech Eng. 2003;125(2):238–45. https://doi.org/10.1115/1.1559896.

    Article  PubMed  Google Scholar 

  21. Riemersma DJ. Van den Bogert, a J, Jansen MO, Schamhardt HC. Tendon strain in the forelimbs as a function of gait and ground characteristics and in vitro limb loading in ponies. Equine Vet J. 1996;28(2):133–8. https://doi.org/10.1111/j.2042-3306.1996.tb01605.x.

    Article  CAS  PubMed  Google Scholar 

  22. Liggins AB, Shemerluk R, Hardie R, Finlay JB. Technique for the application of physiological loading to soft tissue in vitro. J Biomed Eng. 1992;14(5):440–1. https://doi.org/10.1016/0141-5425(92)90092-Y.

    Article  CAS  PubMed  Google Scholar 

  23. Powell ES, Trail IA, Noble J. Non-suture repair of tendons. J Biomed Eng. 1989;11(3):215–8. https://doi.org/10.1016/0141-5425(89)90144-1.

    Article  CAS  PubMed  Google Scholar 

  24. Rincon L, Schatzmann L, Brunner P, Staubli HU, Ferguson SJ, Oxland TR, et al. Design and evaluation of a cryogenic soft tissue fixation device -- load tolerances and thermal aspects. J Biomech. 2001;34(3):393–7. https://doi.org/10.1016/S0021-9290(00)00214-1.

    Article  CAS  PubMed  Google Scholar 

  25. Sharkey NA, Smith TS, Lundmark DC. Freeze clamping musculo-tendinous junctions for in vitro simulation of joint mechanics. J Biomech. 1995;28(5):631–5. https://doi.org/10.1016/0021-9290(94)00100-I.

    Article  CAS  PubMed  Google Scholar 

  26. Jansen MO, van den Bogert AJ, Riemersma DJ, Schamhardt HC. In vivo tendon forces in the forelimb of ponies at the walk, validated by ground reaction force measurements. Acta Anat (Basel). 1993;146:162–7.

    Article  CAS  Google Scholar 

  27. Lawson SE, Chateau H, Pourcelot P, Denoix J-M, Crevier-Denoix N. Effect of toe and heel elevation on calculated tendon strains in the horse and the influence of the proximal interphalangeal joint. J Anat. 2007;210(5):583–91. https://doi.org/10.1111/j.1469-7580.2007.00714.x.

    Article  PubMed  PubMed Central  Google Scholar 

  28. Batson EL, Paramour RJ, Smith TJ, Birch HL, Patterson-Kane JC, Goodship AE. Are the material properties and matrix composition of equine flexor and extensor tendons determined by their functions? Equine Vet J. 2003;35(3):314–8. https://doi.org/10.2746/042516403776148327.

    Article  CAS  PubMed  Google Scholar 

  29. Quinn KP, Winkelstein BA. Preconditioning is correlated with altered collagen fiber alignment in ligament. J Biomech Eng. 2011;133(6):64506. https://doi.org/10.1115/1.4004205.

    Article  Google Scholar 

  30. Woo SL. Mechanical properties of tendons and ligaments. I. Quasi-static and nonlinear viscoelastic properties. Biorheology. 1982;19(3):385–96. https://doi.org/10.3233/BIR-1982-19301.

    Article  CAS  PubMed  Google Scholar 

  31. Thorpe CT, Riley GP, Birch HL, Clegg PD. Screen, hazel R C. effect of fatigue loading on structure and functional behaviour of fascicles from energy-storing tendons. Acta Biomater. 2014;10(7):3217–24. https://doi.org/10.1016/j.actbio.2014.04.008.

    Article  PubMed  Google Scholar 

  32. Sverdlik A, Lanir Y. Time-dependent mechanical behavior of sheep digital tendons, including the effects of preconditioning. J Biomech Eng. 2002;124(1):78–84. https://doi.org/10.1115/1.1427699.

    Article  CAS  PubMed  Google Scholar 

  33. Han S, Gemmell SJ, Helmer KG, Grigg P, Wellen JW, Hoffman AH, et al. Changes in ADC caused by tensile loading of rabbit achilles tendon: evidence for water transport. J Magn Reson. 2000;144(2):217–27. https://doi.org/10.1006/jmre.2000.2075.

    Article  CAS  PubMed  Google Scholar 

  34. Hannafin JA, Arnoczky SP. Effect of cyclic and static tensile loading on water content and solute diffusion in canine flexor tendons: an in vitro study. J Orthop Res. 1994;12(3):350–6. https://doi.org/10.1002/jor.1100120307.

    Article  CAS  PubMed  Google Scholar 

  35. Helmer KG, Wellen J, Grigg P, Sotak CH. Measurement of the spatial redistribution of water in rabbit Achilles tendon in response to static tensile loading. J Biomech Eng. 2004;126(5):651–6. https://doi.org/10.1115/1.1800573.

    Article  CAS  PubMed  Google Scholar 

  36. Thorpe CT, Clegg PD, Birch HL. A review of tendon injury: why is the equine superficial digital flexor tendon most at risk? Equine Vet J. 2010;42(2):174–80. https://doi.org/10.2746/042516409X480395.

    Article  CAS  PubMed  Google Scholar 

  37. Riemersma DJ, Schamhardt HC, Lammertink JL. In vivo tendon load and tendon strain in the horse. Biomechanics: current interdisciplinary research. 1985:731–6.

  38. Riemersma DJ, Schamhardt HC, Hartman W, Lammertink JL. Kinetics and kinematics of the equine hind limb: in vivo tendon loads and force plate measurements in ponies. Am J Vet Res. 1988;49:1344–52.

    CAS  PubMed  Google Scholar 

  39. Takahashi T, Yoshihara E, Mukai K, Ohmura H, Hiraga A. Use of an implantable transducer to measure force in the superficial digital flexor tendon in horses at walk, trot and canter on a treadmill. Equine Vet J Suppl. 2010;38:496–501.

    Article  Google Scholar 

  40. Crevier-Denoix N, Ruel Y, Dardillat C, Jerbi H, Sanaa M, Collobert-Laugier C, et al. Correlations between mean echogenicity and material properties of normal and diseased equine superficial digital flexor tendons: an in vitro segmental approach. J Biomech. 2005;38(11):2212–20. https://doi.org/10.1016/j.jbiomech.2004.09.026.

    Article  CAS  PubMed  Google Scholar 

  41. Kelc R, Naranda J, Kuhta M, Vogrin M. The Physiology of Sports Injuries and Repair Processes. Intech. 2013;Chapter 2:43–86.

    Google Scholar 

  42. Arnold G. Biomechanische und rheologische Eigenschaften menschlicher Sehnen. Zeitschrift für Anatomie und Entwicklungsgeschichte. 1974;143(3):263–300. https://doi.org/10.1007/BF00519870.

    Article  CAS  PubMed  Google Scholar 

  43. Shepherd JH, Legerlotz K, Demirci T, Klemt C, Riley GP, Screen HRC. Functionally distinct tendon fascicles exhibit different creep and stress relaxation behaviour. Proc Inst Mech Eng H. 2014;228(1):49–59. https://doi.org/10.1177/0954411913509977.

    Article  PubMed  Google Scholar 

  44. Thorpe CT, Godinho MSC, Riley GP, Birch HL, Clegg PD, Screen HRC. The interfascicular matrix enables fascicle sliding and recovery in tendon, and behaves more elastically in energy storing tendons. J Mech Behav Biomed Mater. 2015;52:85–94. https://doi.org/10.1016/j.jmbbm.2015.04.009.

    Article  PubMed  PubMed Central  Google Scholar 

  45. Thorpe CT, Riley GP, Birch HL, Clegg PD, Screen HRC. Fascicles and the interfascicular matrix show adaptation for fatigue resistance in energy storing tendons. Acta Biomater. 2016;42:308–15. https://doi.org/10.1016/j.actbio.2016.06.012.

    Article  PubMed  PubMed Central  Google Scholar 

  46. Ciarletta P, Dario P, Micera S. Pseudo-hyperelastic model of tendon hysteresis from adaptive recruitment of collagen type I fibrils. Biomaterials. 2008;29(6):764–70. https://doi.org/10.1016/j.biomaterials.2007.10.020.

    Article  CAS  PubMed  Google Scholar 

  47. Nabeshima Y, Grood ES, Sakurai A, Herman JH. Uniaxial tension inhibits tendon collagen degradation by collagenase in vitro. J Orthop Res. 1996;14(1):123–30. https://doi.org/10.1002/jor.1100140120.

    Article  CAS  PubMed  Google Scholar 

  48. French MF, Mookhtiar KA, van Wart HE. Limited proteolysis of type I collagen at hyperreactive sites by class I and II Clostridium histolyticum collagenases: complementary digestion patterns. Biochemistry. 1987;26(3):681–7. https://doi.org/10.1021/bi00377a004.

    Article  CAS  PubMed  Google Scholar 

  49. Watts AE, Nixon AJ, Yeager AE, Mohammed HO. A collagenase gel/physical defect model for controlled induction of superficial digital flexor tendonitis. Equine Vet J. 2012;44(5):576–86. https://doi.org/10.1111/j.2042-3306.2011.00471.x.

    Article  CAS  PubMed  Google Scholar 

  50. Goodship AE, Birch HL, Wilson AM. The pathobiology and repair of tendon and ligament injury. Vet Clin North Am Equine Pract. 1994;10(2):323–49. https://doi.org/10.1016/S0749-0739(17)30359-0.

    Article  CAS  PubMed  Google Scholar 

  51. Möller HD, Evans CH, Maffulli N. Aktuelle Aspekte der Sehnenheilung. Orthopade. 2000;29(3):182–7. https://doi.org/10.1007/s001320050436.

    Article  PubMed  Google Scholar 

  52. Bosch G, Lameris MC, van den Belt, A J M, Barneveld A, van Weeren, P R The propagation of induced tendon lesions in the equine superficial digital flexor tendon: an ex vivo study Equine Vet J 2010;42:407–411. doi:https://doi.org/10.1111/j.2042-3306.2010.00099.x, 5.

  53. Burk J, Berner D, Brehm W, Hillmann A, Horstmeier C, Josten C, et al. Long-term cell tracking following local injection of mesenchymal stromal cells in the equine model of induced tendon disease. Cell Transplant. 2016;25(12):2199–211. https://doi.org/10.3727/096368916X692104.

    Article  PubMed  Google Scholar 

  54. Crovace A, Lacitignola L, Rossi G, Francioso E. Histological and immunohistochemical evaluation of autologous cultured bone marrow mesenchymal stem cells and bone marrow mononucleated cells in collagenase-induced tendinitis of equine superficial digital flexor tendon. Vet Med Int. 2010;2010:250978–10. https://doi.org/10.4061/2010/250978.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  55. Keg PR, van den Belt AJ, Merkens HW, Barneveld A, Dik KJ. The effect of regional nerve blocks on the lameness caused by collagenase induced tendonitis in the midmetacarpal region of the horse: a study using gait analysis, and ultrasonography to determine tendon healing. Zentralbl Veterinarmed A. 1992;39:349–64.

    Article  CAS  Google Scholar 

  56. Mookhtiar KA, van Wart HE. Clostridium histolyticum collagenases: a new look at some old enzymes. Matrix Suppl. 1992;1:116–26.

    CAS  PubMed  Google Scholar 

  57. Biewener AA. Muscle-tendon stresses and elastic energy storage during locomotion in the horse. Comp Biochem Physiol B Biochem Mol Biol. 1998;120(1):73–87. https://doi.org/10.1016/S0305-0491(98)00024-8.

    Article  CAS  PubMed  Google Scholar 

  58. Riemersma DJ, Schamhardt HC. In vitro mechanical properties of equine tendons in relation to cross-sectional area and collagen content. Res Vet Sci. 1985;39(3):263–70. https://doi.org/10.1016/S0034-5288(18)31711-9.

    Article  CAS  PubMed  Google Scholar 

  59. Crevier-Denoix N, Ravary-Plumioen B, Vergari C, Camus M, Holden-Douilly L, Falala S, et al. Comparison of superficial digital flexor tendon loading on asphalt and sand in horses at the walk and trot. Vet J. 2013;198(Suppl 1):e130–6. https://doi.org/10.1016/j.tvjl.2013.09.047.

    Article  PubMed  Google Scholar 

  60. Addis PR, Lawson SE. The role of tendon stiffness in development of equine locomotion with age. Equine Vet J. 2010;38:556–60.

    Article  Google Scholar 

  61. Birch HL, Bailey JV, Bailey AJ, Goodship AE. Age-related changes to the molecular and cellular components of equine flexor tendons. Equine Vet J. 1999;31(5):391–6. https://doi.org/10.1111/j.2042-3306.1999.tb03838.x.

    Article  CAS  PubMed  Google Scholar 

  62. Jones AJ, Bee JA. Age- and position-related heterogeneity of equine tendon extracellular matrix composition. Res Vet Sci. 1990;48(3):357–64. https://doi.org/10.1016/S0034-5288(18)31027-0.

    Article  CAS  PubMed  Google Scholar 

  63. Patterson-Kane JC, Firth EC, Goodship AE, Parry DA. Age-related differences in collagen crimp patterns in the superficial digital flexor tendon core region of untrained horses. Aust Vet J. 1997;75(1):39–44. https://doi.org/10.1111/j.1751-0813.1997.tb13829.x.

    Article  CAS  PubMed  Google Scholar 

  64. Smith RKW, Birch HL, Goodman S, Heinegard D, Goodship AE. The influence of ageing and exercise on tendon growth and degeneration--hypotheses for the initiation and prevention of strain-induced tendinopathies. Comp. Biochem Physiol Part A Mol Integr Physiol. 2002;133:1039–50.

    Article  CAS  Google Scholar 

  65. Thorpe CT, Udeze CP, Birch HL, Clegg PD, Screen HR. Capacity for sliding between tendon fascicles decreases with ageing in injury prone equine tendons: a possible mechanism for age-related tendinopathy? Eur Cell Mater. 2013;25:48–60. https://doi.org/10.22203/eCM.v025a04.

    Article  CAS  PubMed  Google Scholar 

  66. Thorpe CT, Riley GP, Birch HL, Clegg PD, Screen HRC. Fascicles from energy-storing tendons show an age-specific response to cyclic fatigue loading. J R Soc Interface. 2014;11(92):20131058. https://doi.org/10.1098/rsif.2013.1058.

    Article  PubMed  PubMed Central  Google Scholar 

  67. Kubo K, Kanehisa H, Miyatani M, Tachi M, Fukunaga T. Effect of low-load resistance training on the tendon properties in middle-aged and elderly women. Acta Physiol Scand. 2003;178(1):25–32. https://doi.org/10.1046/j.1365-201X.2003.01097.x.

    Article  CAS  PubMed  Google Scholar 

  68. Reeves ND, Maganaris CN, Narici MV. Effect of strength training on human patella tendon mechanical properties of older individuals. J Physiol. 2003;548(3):971–81. https://doi.org/10.1113/jphysiol.2002.035576.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  69. Faria A, Gabriel R, Abrantes J, Bras R, Moreira H. Biomechanical properties of the triceps surae muscle-tendon unit in young and postmenopausal women. Clin Biomech (Bristol, Avon). 2011;26:523–8. doi:https://doi.org/10.1016/j.clinbiomech.2010.12.011.

  70. Smith CK, Hull ML, Howell SM. Migration of radio-opaque markers injected into tendon grafts: a study using roentgen stereophotogrammetric analysis (RSA). J Biomech Eng. 2005;127(5):887–90. https://doi.org/10.1115/1.1992533.

    Article  PubMed  Google Scholar 

  71. Roos PJ, Hull ML, Howell SM. How cyclic loading affects the migration of radio-opaque markers attached to tendon grafts using a new method: a study using roentgen stereophotogrammetric analysis (RSA). J Biomech Eng. 2004;126(1):62–9. https://doi.org/10.1115/1.1644568.

    Article  CAS  PubMed  Google Scholar 

  72. Ashmore AM, Rout R, Beard DJ, Price AJ, Murray DW, Gill HS. A new technique for the radiostereometric analysis of soft tissues. J Biomech. 2012;45(16):2931–4. https://doi.org/10.1016/j.jbiomech.2012.09.001.

    Article  CAS  PubMed  Google Scholar 

  73. Schepull T, Kvist J, Andersson C, Aspenberg P. Mechanical properties during healing of Achilles tendon ruptures to predict final outcome: a pilot roentgen stereophotogrammetric analysis in 10 patients. BMC Musculoskelet Disord. 2007;8(1):116. https://doi.org/10.1186/1471-2474-8-116.

    Article  PubMed  PubMed Central  Google Scholar 

  74. Aronson AS, Jonsson N, Alberius P. Tantalum markers in radiography. An assessment of tissue reactions. Skelet Radiol. 1985;14(3):207–11. https://doi.org/10.1007/BF00355566.

    Article  CAS  Google Scholar 

  75. Sanctorum JG, Adriaens D, Dirckx JJJ, Sijbers J, van Ginneken C, Aerts P, et al. Methods for characterization and optimisation of measuring performance of stereoscopic x-ray systems with image intensifiers. Meas Sci Technol. 2019;30(10):105701. https://doi.org/10.1088/1361-6501/ab23e7.

    Article  CAS  Google Scholar 

  76. McKetty MH. The AAPM/RSNA physics tutorial for residents. X-ray attenuation. Radiographics. 1998;18(1):151–63; quiz 149. https://doi.org/10.1148/radiographics.18.1.9460114.

    Article  CAS  PubMed  Google Scholar 

  77. Weiss M, Reich E, Grund S, Mulling CKW, Geiger SM. Validation of 2 noninvasive, markerless reconstruction techniques in biplane high-speed fluoroscopy for 3-dimensional research of bovine distal limb kinematics. J Dairy Sci. 2017;100(10):8372–84. https://doi.org/10.3168/jds.2017-12563.

    Article  CAS  PubMed  Google Scholar 

  78. Geiger SM, Reich E, Bottcher P, Grund S, Hagen J. Validation of biplane high-speed fluoroscopy combined with two different noninvasive tracking methodologies for measuring in vivo distal limb kinematics of the horse. Equine Vet J. 2018;50(2):261–9. https://doi.org/10.1111/evj.12717.

    Article  CAS  PubMed  Google Scholar 

  79. Knoerlein BJ, Baier DB, Gatesy SM, Laurence-Chasen JD, Brainerd EL. Validation of XMALab software for marker-based XROMM. J Exp Biol. 2016;219:3701–11. https://doi.org/10.1242/jeb.145383.

    Article  Google Scholar 

Download references

Acknowledgements

The authors would like to thank Dr. Sandra Geiger (Institute of Topographical Anatomy, University of Veterinary Medicine Vienna), Albrecht Jentsch (Werkzeugbau Simon), Prof. Dr. Janina Burk-Luibl (Equine Clinic, Faculty of Veterinary Medicine, University of Gießen), the Small Animal Clinic and the Institute for Veterinary Pathology of the Faculty of Veterinary Medicine/Leipzig University, as well as Tobias Meißner (Department of Cariology, Endodontology and Periodontology of the Faculty of Medicine/Leipzig University) for their support. Thanks also to Dr. Markus Kreuz (Institute for Medical Informatics, Statistics and Epidemiology, Medical Faculty, Leipzig University) for his advice in statistical procedures. We acknowledge support from Leipzig University for Open Access Publishing.

Funding

No external funding was obtained for this research.

Author information

Authors and Affiliations

Authors

Contributions

FCW designed the study in agreement with PB and CKWM, and was the principal investigator and drafted the manuscript. PB participated in the development of methodology. KG performed ultrasonographic examinations. FCW and SR collected and analysed the data. CKWM contributed in funding acquisition and revised the manuscript. All authors critically read and approved the final manuscript.

Corresponding author

Correspondence to Franziska C. Wagner.

Ethics declarations

Ethics approval and consent to participate

Not applicable according to the german German “Tierschutzversuchsverordnung” (Verordnung zum Schutz von zu Versuchszwecken oder zu anderen wissenschaftlichen Zwecken verwendeten Tieren), because material was purchased from an abattoir or provided after a veterinary post mortem examination not related to the study.

Consent for publication

not applicable.

Competing interests

The authors declare that they have no competing interests.

Additional information

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Supplementary Information

Additional file 1.

Video of high-speed fluoroscopy during tensile testing. FluoKin video of one X-ray high-speed camera recorded during cyclic loading of the SDFT with implanted tantalum beads.

Additional file 2.

Failure and cyclic tensile testing of Shetland pony SDFT. During the rupture tests of Shetland pony SDFTs, no slippage of the tendon tissue out of the cryo-clamps nor breakage of the tendon tissue above the clamps occurred. The shown repetitive cyclic testing protocol was carried out with 4% strain for repeated testing over at least 50 min.

Rights and permissions

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Wagner, F.C., Reese, S., Gerlach, K. et al. Cyclic tensile tests of Shetland pony superficial digital flexor tendons (SDFTs) with an optimized cryo-clamp combined with biplanar high-speed fluoroscopy. BMC Vet Res 17, 223 (2021). https://doi.org/10.1186/s12917-021-02914-w

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s12917-021-02914-w

Keywords