Measurement variability of right atrial and ventricular monophasic action potential and refractory period measurements in the standing non-sedated horse

Abstract

Background

In human and veterinary medicine, monophasic action potential (MAP) analysis and determination of local refractory periods by contact electrode technique gives valuable information about local cardiac electrophysiological properties. It is used to investigate dysrhythmias and the impact of drugs on the myocardium. Precise measurement of total MAP duration is difficult, therefore the MAP duration is usually determined at a repolarization level of 90% (APD90). Until now, no studies are published about the feasibility of this technique in the standing non-sedated horse. In 6 healthy Warmblood horses, on two different days, an 8F quadripolar contact catheter was passed through a jugular introducer sheath and placed under ultrasound guidance at the level of the intervenous tubercle or right atrial free wall (RA), and in the right ventricular apex (RV) to record the MAP. The MAP amplitude and APD90 were measured at a resting sinus rhythm (heart rate of 30-42 bpm) and at pacing cycle lengths (PCL) of 1000 and 600 ms. The effective refractory period (ERP) was determined at PCL of 1000 and 600 ms.

Results

The overall mean (±SD) APD90 (rest), APD90 (1000) and APD90 (600) were 263 ± 39 ms, 262 ± 41 ms, 236 ± 47 ms for the RA and 467 ± 23 ms, 412 ± 38 ms, 322 ± 29 ms for the RV. The mean ERP1000 and ERP600 were 273 ± 24 ms and 256 ± 22 ms for the RA and 386 ± 40 ms and 293 ± 30 ms for the RV. The measurement variability for the amplitude, APD90 and ERP measurements in the RA ranged between 36 and 44, 9–22 and 7–8%, respectively. The measurement variability for the amplitude, APD90 and ERP measurements in the RV ranged between 49 and 66, 6–7 and 10–12%, respectively.

Conclusions

RA and RV MAP duration and ERP can be obtained by a contact electrode in standing non-sedated horses. The measurement variability varies with catheter location.

Background

Electrocardiography (ECG) is the most commonly used technique for recording electrical activity of the myocardium. However, it does not provide precise information regarding the dispersion of repolarization or after-depolarizations since an ECG represents the summation of electrical activity of many myocardial cells from a relatively large region of the heart [1]. Local activity can be recorded by an intracellular action potential (IAP). However, IAP recordings can only be made in an individual cardiac cell and thus can only be performed in vitro [2]. Monophasic action potential (MAP) has a smaller magnitude than the IAP but it is proven that MAP recordings can give highly accurate information about local atrial or ventricular activation time and the entire time course of myocardial repolarization [3,4,5,6,7,8,9,10,11]. The local electrical activity of the in situ beating heart can be assessed by monophasic action potentials. This waveform can be obtained by slight pressure of a contact electrode on the heart muscle and is a result of membrane potential discharges (depolarisation) and slowly recharges (repolarisation). MAPs are useful for investigation of the electrophysiology of different dysrhythmias (i.e. effects of cycle length changes and the role of afterdepolarizations in the genesis of triggered dysrhythmias) and the impact of drugs (i.e. the effect of antiarrhythmic drugs on the action potential duration in the in situ heart) on the heart of different species [3,4,5,6,7,8,9,10,11]. The recording of MAP signals in awake dogs without any interference of anaesthetic drugs is possible. With this procedure the effect of anaesthetics drugs on the autonomic nervous system, which has an important impact on cardiac electrophysiology, can be avoided [12, 13]. The underlying principles concerning MAP recordings are described elsewhere [1, 14, 15].

Until now, very little information about the possibility of making MAP recordings in standing horses is available. This paper describes the technique and the day-to-day variability of right cardiac MAP recording and refractory period measurement in the standing non-sedated horse.

Methods

The experimental protocol was approved by the Ethical Committee of the Faculty of Veterinary Medicine and the Faculty of Bioscience Engineering at Ghent University (case number EC 2015/85, date of approval 9th of September, 2015). The horses used in this study are Faculty owned horses.

The study population consisted of 6 healthy warmblood horses (3 geldings, 3 mares) aged (mean ± standard deviation) 10 ± 5 years, with a body weight of 531 ± 70 kg and a height at the withers of 160 ± 6 cm. Cardiovascular or other diseases were excluded based on a physical examination, a complete blood exam, an echocardiographic examination, a 30-min resting ECG and a 20-min standardized exercise ECG. All horses underwent the procedure two times on two different days with at least 2 weeks interval. In each horse an 8.5F introducer sheath (Introflex, Edwards Lifesciences, Dilbeek, Belgium) was placed using the Seldinger technique in the lower third of the jugular vein. An 8F quadripolar contact catheter with separated recording and pacing electrodes (EasyMap MAP, Medfact, Lörrach, Germany) was used [3, 5] (Fig. 1). The catheter was inserted via the introducer sheath and placed under ultrasound guidance at the level of the intervenous tubercle (in 9/12 procedures) or at the level of the right atrial free wall (RA) (in 3/12 procedures) and in the right ventricular apex (RV) (in all procedures =12/12) (Fig. 2). The catheter tip was pressed softly against the endocardium. Exact pressure determination against the wall was not possible with this type of catheter. MAPs were recorded after placement of the catheter in a position that provided continuous recordings with a stable amplitude of > 2 mV in the RA and > 3 mV in the RV, a stable baseline, a sharp positive phase and an upward convex plateau phase [14]. MAP signal and a surface ECG (base-apex) were recorded simultaneously using a multichannel recorder (PowerLab 8/35, ADInstruments, Oxford, United Kingdom) with amplifier (Bio Amp and Quad Bridge Amp, ADInstruments, Oxford, United Kingdom) and digitized on a computer. Measurements were performed off-line using the ECG analysis (used for determination of QT interval) and cardiac action potential peak analysis module of a specialized semi-automatic data analysis software program (LabChart 8, ADInstruments, Oxford, United Kingdom). The minimum peak height detection was set at 1.5 mV and an automatic resting membrane potential detection was used. The MAP signals were amplified using a low-pass filter with settings between 20 and 50 Hz because it reduces noise which results in a smoother signal. Each MAP curve was checked separately and only MAPs where the automatic resting membrane potential was automatically set at the level of true baseline were used. In every horse, 15 cardiac cycles were analysed per chamber and per day. The APD90 was automatically measured by the software as the duration between the upstroke and 90% repolarization. The amplitude was measured as the height from baseline to the crest of the plateau phase. First, measurements were made in sinus rhythm at rest (non-paced) at a cardiac rate between 30 and 42 beats per minute (bpm). Subsequently, to have a more stable rhythm and to follow the impact of heart frequency on action potential characteristics, the pacing electrodes of the MAP catheter were connected to a pacemaker programmer (Medtronic, Jette, Belgium) and pacing was performed at a pacing cycle length of 1000 and 600 ms to record MAPs at each pacing rate. Finally, atrial and ventricular effective refractory period (ERP) were determined as previously described [16, 17]. In brief, after pacing for 2 min with a fixed pacing interval (S1-S1), an extra stimulus (S2), at two times threshold amplitude, was introduced with a coupling interval (S1-S2) below the expected refractory period. The coupling interval was increased in steps of 8 ms until capture of the extra stimulus occurred (the atrial or ventricular S2 was followed by a P wave or QRS complex on the surface ECG, respectively). The longest S1-S2 interval without capture was taken as the effective refractory period. ERP was always determined 5 times to obtain a mean value. After the procedure, all catheters were gently removed under ultrasound guidance.

Fig. 1
figure 1

Illustration of the tip of an 8F quadripolar contact catheter with separated recording and pacing electrodes

Fig. 2
figure 2

Ultrasound images of the contact MAP electrode (arrow) positioned at the level of the intervenous tubercle (IT) in the right atrium (a), at the level of the right atrial free wall (b) and in the right ventricular apex (c). RA: right atrium, TV: tricuspid valve, RV: right ventricle, LV: left ventricle, IVS: interventricular septum

Data analysis

Statistical analyses were performed using dedicated software (SPSS Statistics 22.0, SPSS Inc., Chicago, Illinois). Mean and standard deviation (SD) were calculated from pooled measurements of all examinations for each horse. Measurement variability was obtained by comparing the results of the measurements from day 1 and day 2 in a one-way repeated measures analysis of variance with the horse as the unit of repeated measure. The numerical values for the reported coefficients of variation (CV) were calculated by dividing the square root of the mean square error (MSE) by the grand mean, multiplied by 100. The relationship between QT interval and APD90 was evaluated using a linear regression model with QT interval, day and horse as predictors. A value of P < 0.05 was considered significant.

Results

Right atrial (Fig. 3a) and right ventricular (Fig. 3b) MAP recordings of sufficient quality could be obtained and analysed in non-sedated standing horses. However, horse movements, occasionally resulted in loss of contact requiring MAP catheter repositioning. The total recording time per horse and per day ranged between 35 and 165 min. Catheter positioning was occasionally associated with self-limiting atrial or ventricular depolarizations which terminated after slight catheter tip movements. During atrial ERP measurements, a short episodes of self-limiting episode of atrial tachycardia was occasionally found and 1 horse showed a 20-min paroxysm of atrial fibrillation. Ventricular ERP measurements were never associated with tachyarrhythmias. No complications were observed after the procedure. Typical right atrial and ventricular MAP recordings are shown in Fig. 3. All the results of the two different days are shown in Table 1 and Fig. 4. In 1 horse a difference of up to 100 ms was observed during VERP1000 measurement. The QT interval was a significant predictor of APD90 in sinus rhythm (beta 0.604, P < 0.001) and at a pacing cycle length of 1000 ms (beta − 0.177, P = 0.018), but not at a pacing cycle length of 600 ms.

Fig. 3
figure 3

Surface electrocardiogram (ECG) with corresponding right atrial (a) and right ventricular (b) monophasic action potential (MAP) at resting sinus heart rhythm in the standing non-sedated horse

Table 1 Mean ± SD of monophasic action potential amplitude and repolarization level of 90% (APD90), and effective refractory periods (ERP) measured at rest and at a pacing cycle length of 1000 and 600 ms in the right atrium and right ventricle
Fig. 4
figure 4

Graphical illustration of monophasic action potential amplitude (a and d) and repolarization level of 90% (APD90) (b and e), and effective refractory periods (ERP) (c and f) measured at rest (sinus rhythm: SR) and at a pacing cycle length of 1000 and 600 ms in the right atrium (RA) (a, b and c) and right ventricle (RV) (d, e and f) in two different days. The median and spread of the value is indicated by a boxplot, with the box span indicating the middle half of the observations, the line in the box marking the median, and the whiskers indicating the range of observations. Extreme values were plotted individually at the end of the whiskers

Discussion

The present paper describes the technique to determine right atrial and right ventricular repolarization and refractoriness in the standing non-sedated horse. In humans, dogs, cats and pigs, MAP recordings play an important role in the investigation of myocardial electrophysiology under physiological, pathological and pharmacological conditions and have a low level of risk [18,19,20,21]. However, complications such as sustained dysrhythmias, movement artefacts or pericardial effusion have been reported [21]. In our study, complications were limited to some short episodes of ectopic rhythms and 1 short episode of atrial fibrillation during ERP measurement. The ERP values in our study were comparable with previously reported results [17]. The coefficient of variation of the ERP measurements ranged between 7 and 12% but in one horse the difference in VERP1000 measurement was > 100 ms. As observed in awake dogs, neck and body movements of the horse occasionally resulted in dislocation of the catheter and loss of tip pressure increasing recording time and measurement variability [12]. Due to a more fixed catheter position in the apex, dislodgement of the catheter tip was less frequently observed in ventricular MAP recordings. Probably, some spatial repolarization differences might also contribute to the measurement variability [12, 18]. MAP duration and amplitude can be variable due to angle differences of the catheter tip relative to the myocardium, the catheter location and varying endocardial contact pressures in the beating heart [14, 22]. Prolonged good quality MAP recordings from the same endocardial site (up to 1 h), as described for awake dogs, could not be achieved in our horses [13]. Mild sedation or the use of another type of catheter could have facilitated the procedure in our study. In humans and sedated dogs, the MAP amplitude of the atrium and ventricle ranges between 5 and 50 mV due to a variability in contact pressure but also due to tissue type and species [12, 14, 22]. The difference in amplitude between the atrium and the ventricle has partly been explained by the different thickness of the endocardial tissue beneath the tip of the catheter [12]. The reason for the species- and tissue-related difference in MAP amplitude remains unexplained [21]. Intracellular recordings have amplitudes of approximately 120 mV regardless species or tissue dependence [22]. The MAP amplitude in our horses ranged between 2 and 10 mV for the atrium and between 3 and 16 mV for the ventricle, which could be related to endocardial properties. The large size of the equine heart seems to be a large disadvantage and also has probably contributed to a less stable catheter position. The most frequently used filters with MAP measurements are the low-pass filter and the high-pass filter. The manuals of the used program advice to use a low-pass filter since it lets low frequencies pass and stops high frequencies. This results in a reduction of noise, it gives a smoother MAP signal. The use of a high pass filter lets high frequencies pass and remove any steady component or slow fluctuations from the signal. This setting is used to stabilize baseline. In this study, a low pass filter was used to obtain smoother MAP signals. In addition, each MAP signal was checked manually to evaluate if the automatic resting membrane potential was correctly set at the level of baseline.

Study limitations

Despite ultrasonographic guidance, dislocation of the catheter and changes in contact pressure by the beating heart and horse movements contributed to the variability. Further research is necessary to identify whether repeating the measurements in a higher number of horses, harder pressure on the catheter tip, measurement under general anaesthesia or using another type of catheter (with i.e. a spring-steel stylet that is inserted into the myocardium) results in a lower variability in horses. Also the influence of spatial differences within right atrium and right ventricle, and between the left and right heart should be investigated. In humans, access to the left heart is possible transseptal or via the arteria femoralis [23,24,25]. In horses, access to the left heart might be possible via the carotid artery or transseptal.

The present study describes the feasibility and measurement variability of MAP recordings and refractory period measurements with a quadripolar contact catheter in the standing non-sedated horse. Further research is necessary to evaluate if this MAP recording technique might be useful to investigate equine dysrhythmias and the impact of drugs on the myocardium.

Conclusion

RA and RV MAP duration and ERP can be obtained by a contact electrode in standing non-sedated horses. The measurement variability varies with catheter location.

Abbreviations

APD90:

Action potential at a repolarization of 90%

bpm:

Beats per minute

CV:

Coefficient of variation

ECG:

Electrocardiography

ERP:

Effective refractory period

Hz:

Hertz

MAP:

Monophasic action potential

ms:

Milliseconds

MSE:

Mean square error

mV:

Millivolt

PLC:

Pacing cycle length

RA:

Right atrium

RV:

Right ventricle

SD:

Standard deviation

References

  1. Yang SG, Kittnar O. New insights into application of cardiac monophasic action potential. Physiol Res. 2010;59:645–50.

    CAS  PubMed  Google Scholar 

  2. Behrens S, Franz MR. In vivo registration of monophasic action potentials - new possible applications in clinical electrophysiology. Z Kardiol. 1996;85:231–42.

    Google Scholar 

  3. Franz MR. Long-term recording of monophasic action potentials from human endocardium. Am J Cardiol. 1983;51:1629–34.

    Article  CAS  PubMed  Google Scholar 

  4. Franz MR, Burkhoff D, Spurgeon H, Weisfeldt ML, Lakatta EG. In vitro validation of a new cardiac catheter technique for recording monophasic action potentials. Eur Heart J. 1986;7:34.

    Article  CAS  PubMed  Google Scholar 

  5. Ino T, Karagueuzian HS, Hong K, Meesmann M, Mandel WJ, Peter T. Relation of monophasic action potential recorded with contact electrode to underlying transmembrane action potential properties in isolated cardiac tissues: a systematic microelectrode validation study. Cardiovasc Res. 1988;22:255–64.

    Article  CAS  PubMed  Google Scholar 

  6. Franz MR, Chin MC, Sharkey HR, Griffin JC, Scheinman MM. A new single catheter technique for simultaneous measurement of action potential duration and refractory period in vivo. J Am Coll Cardiol. 1990;16:878–86.

    Article  CAS  PubMed  Google Scholar 

  7. Franz MR. Method and theory of monophasic action potential recording. Prog Cardiovasc Dis. 1991;33:347–68.

    Article  CAS  PubMed  Google Scholar 

  8. Franz MR. Bridging the gap between basic and clinical electrophysiology: what can be learned from monophasic action potential recordings? J Cardiovasc Electrophysiol. 1994;5:699–710.

    Article  CAS  PubMed  Google Scholar 

  9. Eckardt L, Haverkamp W, Borggrefe M, Breithardt G. Experimental models of torsade de pointes. Cardiovasc Res. 1998;39:178–93.

    Article  CAS  PubMed  Google Scholar 

  10. Kirchhof P, Eckardt L, Mönnig G, Johna P, Loh E, Schulze-Bahr G, Breithardt M, Borggrefe W, Haverkamp J. A patient with “atrial torsades de pointes”. J Cardiovasc Electrophysiol. 2000;11:806–11.

    Article  CAS  PubMed  Google Scholar 

  11. Moore HJ, Franz MR. Monophasic action potential recordings in humans. J Cardiovasc Electrophysiol. 2007;18:787–90.

    Article  PubMed  Google Scholar 

  12. Eckardt L, Meissner A, Kirchhof P, Weber T, Borggrefe M, Breithart G, Van Aken H, Haverkamp W. In vivo recording of monophasic action potentials in awake dogs – new applications for experimental electrophysiology. Basic Res Cardiol. 2001;96:169–74.

    Article  CAS  PubMed  Google Scholar 

  13. Eckardt L, Meissner A, Kirchhof P, Weber T, Milberg P, Breithardt G, Haverkamp W. In vivo recording of monophasic action potentials in awake dogs. Methods. 2003;30:109–14.

    Article  CAS  PubMed  Google Scholar 

  14. Franz MR. Current status of monophasic action potential recording: theories, measurements and interpretations. Cardiovasc Res. 1999;41:25–40.

    Article  CAS  PubMed  Google Scholar 

  15. Knollmann BC, Tranquillo J, Sirenko SG, Hendriquez C, Franz MR. Microelectrode study of the genesis of the monophasic action potential by contact electrode. Technique J Cardiovasc Electrophysiol. 2002;12:1246–52.

    Article  Google Scholar 

  16. van Loon G, Fonteyne W, Rottiers H, Tavernier R, Jordaens L, D’Hont L, Colpaert R, De Clercq T, Deprez P. Dual-chamber pacemaker implantation via the cephalic vein in healthy horses. J Vet Intern Med. 2001;15:564–71.

    Article  CAS  PubMed  Google Scholar 

  17. De Clercq D, van Loon G, Tavernier R, Duchateau L, Deprez P. Atrial and ventricular electrical and contractile remodeling and reverse remodeling owing to short-term pacing-induced atrial fibrillation in horses. J Vet Intern Med. 2008;22:1353–9.

    Article  CAS  PubMed  Google Scholar 

  18. Franz MR, Bargheer K, Rafflenbeul W, Haverich A, Lichtlen PR. Monophasic action potential mapping in human subjects with normal electrocardiograms: direct evidence for the genesis of the T wave. Circulation. 1987;75:379–86.

    Article  CAS  PubMed  Google Scholar 

  19. Morgan JM, Cunningham D, Rowland E. Dispersion of monophasic action potential duration: demonstrable in humans after premature ventricular extra stimulation but not in steady state. J Am Coll Cardiol. 1992;19:1244–53.

    Article  CAS  PubMed  Google Scholar 

  20. Leirner AA, Cestari IA. Monophasic action potential. New uses for an old technique. Arq Bras Cardiol. 1999;72:237–42.

    Article  Google Scholar 

  21. Tsuburaya R, Yasuda S, Ito Y, Shiroto T, Gao JI, Ito K, Shimokawa H. Eicosapentaenoic acid reduces ischemic ventricular fibrillation via altering monophasic action potential in pigs. J Mol Cell Cardiol. 2011;3:329–36.

    Article  Google Scholar 

  22. Lerman BB, Burkhoff D, Yue DT, Franz MR, Sagawa K. Mechanoelectrical feedback: independent role of preload and contractility in modulation of canine ventricular excitability. J Clin Invest. 1985;76:1843–50.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  23. Ross J, Braunwald E, Morrow AG. Left heart catheterization by the transseptal route: a description of the technique and its applications. Circ. 1960;22:927-34.

  24. Early MJ. How to perform a trasseptal puncture. Heart. 2009;95:85-92.

  25. Justino H, Petit CJ. Percutaneous common carotid artery access for pediatric interventional cardiac catheterization. Circ Cardiovasc Interv. 2016;9:1-9.

Download references

Acknowledgements

None

Funding

No funding was received for this study.

Availability of data and materials

The datasets used and/or analysed during the current study are available from the corresponding author on reasonable request.

Author information

Authors and Affiliations

Authors

Contributions

DDC and GvL contributed to the study design. DDC performed the measurements. DDC and AD contributed to statistical data analysis and interpretation. DDC, BB and LV contributed to the practical execution of the study. All authors read and critically revised and approved the final manuscript.

Corresponding author

Correspondence to Dominique De Clercq.

Ethics declarations

Ethics approval and consent to participate

The experimental protocol was approved by the Ethical Committee of the Faculty of Veterinary Medicine and the Faculty of Bioscience Engineering at Ghent University (case number EC 2015/85, date of approval 9th of September, 2015).

Consent for publication

Not Applicable.

Competing interests

The authors declare that they have no competing interests.

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

De Clercq, D., Broux, B., Vera, L. et al. Measurement variability of right atrial and ventricular monophasic action potential and refractory period measurements in the standing non-sedated horse. BMC Vet Res 14, 101 (2018). https://doi.org/10.1186/s12917-018-1399-y

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s12917-018-1399-y

Keywords