Skip to main content

Table 6 Results of the association between ARFI electrographic findings and malignancy of canine cutaneous and subcutaneous neoplasms

From: Malignancy prediction of cutaneous and subcutaneous neoplasms in canines using B-mode ultrasonography, Doppler, and ARFI elastography

Characteristic

P-value

Se (%)

Sp (%)

Ac (%)

PPV (%)

NPV (%)

AUC (%)

Deformability

< 0.001

90.2

35.48

87.09

81.3

55.00

SWV

0.024

54.1

68.7

62.7

  1. SWV shear wave velocity; Se sensitivity; Sp specificity; Ac accuracy; PPV positive predictive value; NPV negative predictive value; AUC area under the curve