Table 3 Results of the ID Screen® ELISA and the BIO K302 ELISA as performed by the six laboratories each testing the same 180 serum samples. The mean of the two duplicate runs was used to categorise the sample as seropositive or seronegative using a cut-off for the S/P coefficient suggested by the manufacturer together with the kit (≥ 60% for the ID Screen® ELISA, and > 37% for the BIO K302 ELISA). Serum samples originated from cattle populations where M. bovis is known to be prevalent (the high-prevalence area: Finland, France, the Netherlands and the United Kingdom) and from a cattle population which was considered highly unlikely to have been exposed to M. bovis (the low-prevalence area: northern Sweden)

From: A European inter-laboratory trial to evaluate the performance of three serological methods for diagnosis of Mycoplasma bovis infection in cattle using latent class analysis

 

Number (%) of ELISA tests

ID Screen® ELISA

BIO K302 ELISA

ELISA result

High prevalence area

Low prevalence area

All samples

High prevalence area

Low prevalence area

All samples

Positive

471 (87.2)

2 (0.4)

473 (43.8)

248 (45.9)

64 (11.9)

312 (28.8)

Negative

69 (12.8)

538 (99.6)

607 (56.2)

292 (54.1)

476 (88.1)

768 (71.1)

All

540

540

1080

540

540

1080