Table 2 The percentage of seropositive serum samples (n = 180) for M. bovis infections in two duplicate runs of the ID Screen® ELISA (using a cut-off for the S/P coefficient ≥ 60% as suggested by the manufacturer together with the kit) and the BIO K302 ELISA (using a cut-off for the S/P coefficient > 37% as suggested by the manufacturer together with the kit) at the six laboratories participating in the ring trial

From: A European inter-laboratory trial to evaluate the performance of three serological methods for diagnosis of Mycoplasma bovis infection in cattle using latent class analysis

 

ID Screen® ELISA

BIO K302 ELISA

Lab no.

Duplicate 1

(%)

Duplicate 2

(%)

Mean of the two duplicates (%)

Duplicate 1

(%)

Duplicate 2

(%)

Mean of the two duplicates (%)

1

43.3

43.3

43.3

20.6

20.6

20.6

2

45.0

44.4

45.0

54.4

65.6

61.1

3

42.2

43.3

42.8

38.9

26.7

32.8

4

46.1

45.0

45.6

23.9

23.3

23.3

5

43.3

43.3

43.3

16.1

16.1

16.7

6

42.8

42.2

42.8

19.4

20.0

20.0

All

43.8

43.6

43.8

28.9

28.7

29.1