Skip to main content

Table 1 Detection results for clinical samples

From: Development of a droplet digital PCR assay to detect bovine alphaherpesvirus 1 in bovine semen

Groups

Quantitative real-time PCR

Droplet digital PCR

Positive

Negative

Suspicious

Positive

Negative

Single samples

40

10

0

40

10

Mixed samples

NO. 1

8

0

0

8

0

NO. 2

8

0

0

8

0

NO. 3

7

0

1

8

0

NO. 4

6

0

2

8

0

Total

69

10

3

72

10

Positive rate%

84.1%

87.8%