Table 2 Material Data Sheet GreenTEC Pro® [17]

From: The effect of steam sterilization on different 3D printable materials for surgical use in veterinary medicine

Test

Method

Value/Unit

Flexural modulus

ISO 527

4400 MPa

Tensile strength

ISO 527

61 MPa

Elongation at break

ISO 527

3,4%

Elongation at break

ISO 527

50 MPa

Elongation at impact

ISO 527

3%

Notched impact strength

ISO 179-1/1 eA

4,4 kj/m2

Impact resistance

ISO 179-171 eU

72kj/m2

Melt flow index (MFR)

ISO 1133

12 g/10 min

Melting temperature

ISO 3146-C

190–210 °C

VICAT A (VST)

ISO 306

160 °C

Dimensional stability (HDT/B)

ISO 75

115 °C

Shrinkage

ISO 294-4

0,4%

Tightness

ISO 1183

1,39 g/cm3