Skip to main content

Table 2 Mean ± standard deviation values for comparisons of measurements obtained from 3D-CT, 3D-FDM, and 3D-GAS images of the tibial bone surfaces (n = 12) of six canine cadavers

From: Geometric accuracy of an acrylonitrile butadiene styrene canine tibia model fabricated using fused deposition modelling and the effects of hydrogen peroxide gas plasma sterilisation

Variable

EFDM-CT (3D-FDM vs. 3D-CT)

EGAS-FDM (3D-GAS vs. 3D-FDM)

Surface deviation

 Root mean square (mm)

0.1214 ±0.0185 a

0.0431 ±0.0248

 Average deviation positive (mm)

0.0973 ±0.0182 a

0.0234 ±0.0162

 Average deviation negative (mm)

−0.0737 ±0.0170 a

− 0.0258 ±0.0196

Curvature difference of cross-sectional measurements of bone surface at:

 (a) 5% length of the tibia (mm)

0.3025 ±0.2159 b

0.0491 ±0.0428

 (b) 15% length of the tibia (mm)

0.0863 ±0.0227

0.0273 ±0.0180

 (c) 25% length of the tibia (mm)

0.0645 ±0.0186

0.0247 ±0.0137

 (d) 50% length of the tibia (mm)

0.1313 ±0.0449

0.0376 ±0.0404

 (e) 75% length of the tibia (mm)

0.1307 ±0.0385

0.0263 ±0.0194

 (f) 85% length of the tibia (mm)

0.1020 ±0.0353

0.0239 ±0.0160

 (g) 95% length of the tibia (mm)

0.1288 ±0.0674

0.0351 ±0.0346

  1. a P < 0.0001.b P < 0.0001