Skip to main content

Table 1 Comparison of the detection of PCV3 in clinical samples by polymerase spiral reaction (PSR) and loop-mediated isothermal amplification (LAMP)

From: Novel polymerase spiral reaction assay for the visible molecular detection of porcine circovirus type 3

Province

Date

Tissues

Detection positive rate for different assay

LAMP

PSR

Jiangsu

2017.11

spleen

15/17a

15/17

Hunan

2018.01

pooled liver and spleen

13/19

13/19

Hubei

2018.02

spleen

21/24

21/24

Hubei

2018.03

spleen

6/11

6/11

Hunan

2018.04

pooled liver and spleen

4/14

5/14

Anhui

2018.05

spleen

8/12

8/12

  1. aThe two figures indicate the number of positive results/the number of samples