Skip to main content

Table 1 Comparison of cyclic displacement, stiffness, and comparison between SWP, SOP, and VAP fixations

From: Ex vivo biomechanical comparison of 2.7 mm string-of-pearl plate versus screw/wire/Polymethylmethacrylate composite fixation and 2.7 mm veterinary acetabular plate for repair of simulated canine acetabular fractures

Fixation

Displacement (mm)

Stiffness at 100 Cycles (N/mm)

Stiffness at 500 Cycles (N/mm)

Stiffness at 1000 Cycles (N/mm)

Stiffness at 7500 Cycles (N/mm)

Stiffness at 14750 Cycles (N/mm)

SWP

0.77

415.3

595.27

626.53

695.77

665.16

SOP

0.682

527.15

463.13

483.98

526.91

496.94

VAP

0.799

508.69

548.01

557.14

555.18

546.42

p-value

0.8

0.414

0.6014

0.5336

0.2732

0.3298

  1. SWP screw/wire/polymethylmethacrylate, SOP string-of-pearls™ plate, VAP veterinary acetabular plate, Values reported as mean