Skip to main content

Table 1 Median and range of the RMSSD values of 14 horses before (in atrial fibrillation (AF)) and after cardioversion (in sinus rhythm (SR))

From: Can heart rate variability parameters derived by a heart rate monitor differentiate between atrial fibrillation and sinus rhythm?

Pace

Method

Artifact correction

RMSSD AF

RMSSD SR

P-value

Median

Range

Median

Range

Rest

ECGMan

none

670

248–1409

85

26–378

0.024*

Rest

ECGAut

none

674

244–1409

118

26–580

0.024*

Rest

ECGAut

Kubios very low

216

194–293

87

26–181

.0.024*

Rest

ECGAut

Kubios low

195

160–233

82

16–175

0.024*

Rest

ECGAut

Kubios moderate

145

125–193

72

26–145

0.024*

Rest

ECGAut

Kubios high

78

61–112

61

25–94

0,79

Rest

ECGAut

Kubios very high

23

13–98

30

18–56

1

Rest

HRM

Polar Flow

233

72–329

78

32–169

0.024*

Walk

ECGMan

None

229

84–495

43

11–185

0.024*

Walk

ECGAut

None

226

153–495

83

11–194

0.024*

Walk

ECGAut

Kubios very low

189

124–236

34

11–113

0.024*

Walk

ECGAut

Kubios low

163

117–219

34

11–104

0.024*

Walk

ECGAut

Kubios moderate

135

105–161

34

11–79

0.024*

Walk

ECGAut

Kubios high

82

62–102

28

11–63

0.024*

Walk

ECGAut

Kubios very high

33

11–52

22

10–45

1

Walk

HRM

Polar Flow

126

49–167

32

6–73

0.024*

Trot

ECGMan

None

89

53–144

10

5–18

0.024*

Trot

ECGAut

None

125

34–377

86

7–221

1

Trot

ECGAut

Kubios very low

93

52–187

13

7–58

0.024*

Trot

ECGAut

Kubios low

84

48–124

13

7–53

0.024*

Trot

ECGAut

Kubios moderate

71

43–122

13

7–36

0.024*

Trot

ECGAut

Kubios high

52

34–85

13

7–32

0.024*

Trot

ECGAut

Kubios very high

22

14–49

11

5–32

0,22

Trot

HRM

Polar Flow

37

25–108

6

5–16

0.024*

  1. Two-minute recordings at rest, walk and trot were analyzed using 4 different methods of RR detection and HRV analysis. The automatically analyzed ECG followed by beat-to-beat manual correction of QRS detection (ECGMan) with HRV analysis using Kubios HRV Software without artifact filter was considered the gold standard method. HRM Polar heart rate monitor (Equine H7) with plastic electrodes and Polar Flow Software. ECGAut ECG with automatic RR interval detection (Televet 100) and Kubios HRV software with 5 different artifact correction levels. The artifact correction algorithm identifies every RR interval that differs from the average RR interval of the 2-min recording more than a specified threshold value as artifacts and replaces the corrupted RR interval by interpolated RR values. The threshold values used in this study were 0.45 s (very low artifact correction), 0.35 s (low), 0.25 s (moderate), 0.15 s (high) and 0.05 s (very high). * Indicates significant differences