GROUP 1 (1 ml / kg / h) N = 11
|
GROUP 2 (2 ml / kg / h) N = 9
|
Institutional reference ranges
|
---|
ROTEM
|
T0
|
T1
|
T0
|
T1
| |
---|
In-TEM®
|
CT (s)
|
180 (132–268)
|
166 (61–209)
|
188 (112–279)
|
141 (108–240)
|
126–363 s
|
CFT (s)
|
63 (45–132)
|
59 (41–113)
|
73 (41–86)
|
58 * (38–81)
|
47–224 s
|
MCF (mm)
|
72 (56–80)
|
72 (58–88)
|
68 (62–77)
|
72 (62–78)
|
50–75 mm
|
α angle (°)
|
77 (65–81)
|
79 (69–82)
|
76 (73–82)
|
78 * (74–82)
|
55–81 °
|
Ex-TEM®
|
CT (s)
|
44 (27–61)
|
45 (20–77)
|
46 (30–89)
|
40 (33–80)
|
29–92 s
|
CFT (s)
|
67 (38–159)
|
78 (49–132)
|
81 (51–96)
|
62 (49–92)
|
54–275 s
|
MCF (mm)
|
77 (60–82)
|
70 (64–83)
|
70 (66–81)
|
72 * (67–86)
|
36–73 mm
|
α angle (°)
|
76 (61–83)
|
76 (65–82)
|
74 (71–80)
|
77 * (73–81)
|
47–79 °
|
Fib-TEM®
|
CT (s)
|
47 (31–107)
|
39 (21–57)
|
45 (29–92)
|
39 (32–80)
|
14–102 s
|
MCF (mm)
|
25 (7–38)
|
16 (8–46)
|
15 (9–30)
|
20 (14–78)
|
6–26 mm
|
α angle (°)
|
77,5 (70–86)
|
76 (30–86)
|
76,5 (67–81)
|
77 (71–84)
|
40–78 °
|
MCEplatelet
|
294 (142–404)
|
211 (169–441)
|
206 (175–383)
|
235 (183–571)
|
50–235
|
Standard coagulation
|
aPTT (s)
|
12.5 (9.6–15.4)
|
12.3 (8.7–16)
|
13.9 (12.1–16)
|
14.5 (11.7–16)
|
12–16 s
|
PT (s)
|
7.5 (6.6–9.6)
|
7.15 (6.6–9.9)
|
7.4 (6.2–10)
|
7.3 (6.3–10)
|
8–10 s
|
Fibrinogen (g/L)
|
3.5 (2.5–8.5)
|
3.6 (2.4–7.9)
|
3.4 (2.2–7.4)
|
4.1 (2.2–7.1)
|
1.5–4.50 (g/L)
|
- Values are expressed as median (minimum-maximum)