Skip to main content

Table 3 Comparison of this experiment with other studies data reporting in vitro parameters of CP in plasma, SSP + and Composol - using 35% of residual plasma for the PAS - in different processing methods, plastic bags material and storage times

From: In vitro properties of concentrated canine platelets stored in two additive solutions: a comparative study

Assessed data Plasma SSP+ Composol
% residual plasma 100% 100% 100% 100% 100% 35% 35% 35% 35% 35%
PC method PRP PRP PRP PRP PRP PRP BC BC BC PRP
N 64 8* 22* 15* 13* 13* 35 23 10 14*
PC storage conteiners DEHP-PVC DEHP-PVC TOTM-PVC TOTM-PVC TOTM-PVC TOTM-PVC Varied Varied Polyolefin TOTM-PVC
Leukoreduction Yes No No No No No Yes Yes Yes No
Storage time (days) 5 7 7 9 5 9 8 8 9 9
pH (day 5) 6.7 ± 0.26 7.30 ± 0.3 6.7 ± 0.2 > 7.0 6.1 ± 0.59 6.36 ± 0.15 > 6.6 > 6.6 6.93 ± 0.12 6.04 ± 0.67
Swirling (day 5) > 2 Uninformed > 2 Uninformed 2.07 ± 0.95 2.76 ± 0.43 Appropriate 2.0 ± 0.7 2.35 ± 1
Reference Singh et al., 2009 [22] Hoareau et al., 2014 [46] Costa et al., 2011 [47] Sink, 2002 [48] This study van der Meer et al., 2010 [49] Van der meer, 2001 [50] This study
  1. *Data from studies with dogs