Skip to main content

Table 4 Concordance analyses estimating the reproducibility and error generated by OAB landmark placements

From: Canine atlantoaxial optimal safe implantation corridors – description and validation of a novel 3D presurgical planning method using OsiriX™

Angle

Value 1

Value 2

n

R2

ρc

Low TL

Up TL

Low CI

Up CI

Bias (°)

P-value

ProjA

GS

Single value

1104

0.9970

0.9985

−1.62

1.61

−0.05

0.04

−0.006

0.801

GS

Mean 2 Obs

552

0.9992

0.9996

−0.83

0.83

−0.04

0.03

−0.003

0.861

Obs1

Obs2

552

0.9912

0.9956

−2.85

2.79

−0.15

0.08

−0.032

0.579

Obs1-Sag

Obs2-Sag

264

0.9909

0.9955

−3.37

3.25

−0.25

0.13

−0.060

0.533

Obs1-Tr

Obs2-Tr

144

0.9815

0.9905

−2.02

2.27

−0.04

0.29

0.123

0.135

Obs1-Dors

Obs2-Dors

144

0.9844

0.9921

−2.96

2.69

−0.35

0.08

−0.137

0.207

Obs1-C1

Obs2-C1

192

0.9621

0.9808

−3.58

3.72

−0.17

0.32

0.074

0.549

Obs1-C2

Obs2-C2

360

0.5493

0.9976

−2.48

2.31

−0.21

0.03

−0.089

0.142

GS

Mean 2 Rep

552

0.9984

0.9992

−1.18

1.18

−0.05

0.05

−0.001

0.957

Rep1

Rep2

552

0.9943

0.9971

−2.33

2.20

−0.16

0.03

−0.065

0.163

Rep1-Sag

Rep2-Sag

264

0.9941

0.9970

−2.77

2.58

−0.25

0.06

−0.098

0.211

Rep1-Tr

Rep2-Tr

144

0.9846

0.9922

−1.97

1.95

−0.16

0.14

−0.008

0.916

Rep1-Dors

Rep2-Dors

144

0.9918

0.9959

−2.11

1.98

−0.22

0.09

−0.063

0.421

Rep1-C1

Rep2-C1

192

0.9795

0.9890

−2.92

2.56

−0.36

0.00

−0.179

0.054

Rep1-C2

Rep2-C2

360

0.9965

0.9983

−2.06

2.05

−0.11

0.10

0.930a

−0.005

  1. Bold font: most clinically relevant concordance analyses including comparisons with GS and widest tolerance limit intervals
  2. n number of measures compared, R 2 correlation coefficient, ρ c concordance coefficient, TL 95 % tolerance interval limit (in degrees), CI 95 % confidence interval limits (in degrees), GS gold standard (mean of 4 values), Obs observer, Rep repeat, Sag sagittal ProjA, Tr transverse ProjA, Dors dorsal ProjA, C1 angle projected in C1 system, C2 angle projected in C2 system
  3. astatistically significant bias (considered clinically non-significant)