Skip to main content

Table 1 Validation of analytical method used for determination of ABZ, ABZ-NH3, ABZ-SO and ABZ-SO2 concentrations in plasma

From: Comparative pharmacokinetics and bioavailability of albendazole sulfoxide in sheep and goats, and dose-dependent plasma disposition in goats

 

ABZ-NH3

ABZ-SO

ABZ-SO2

ABZ

LOD (μg/ml)

0.015

0.016

0.016

0.017

LOQ (μg/ml)

0.042

0.045

0.045

0.050

Range of linearity (μg/ml)

0.05-20

0.05-20

0.05-20

0.05-20

Linearity (r 2)

0.997

0.999

0.998

0.996

Recovery (%)

63.69 (5.42)

94.10 (6.39)

91.90 (4.88)

69.29 (6.21)

Coefficient of variation (%)

6.89

5.35

6.33

7.75

Retention times (min)

5.37

5.77

6.81

9.95

  1. LOD limit of detection, LOQ limit of quantification. Values in the brackets represent the coefficient of variations for the recovery assays, r: correlation coefficient