Skip to main content

Table 2 Low-field (0.27 T) and high-field (9.4 T) MR imaging data

From: Axial osteitis of the proximal sesamoid bones and desmitis of the intersesamoidean ligament in the hindlimb of Friesian horses: review of 12 cases (2002-2012) and post-mortem analysis of the bone-ligament interface

 

TR (ms)

TE (ms)

TI (ms)

Flip angle (°)

Slice thickness (mm)

NEX

FOV (mm)

Matrix

Pixel size (μm)

Low-field (0.27 T)

         

Flash 3 dimensional T1 GRE

34

12

 

30

1.07

4

160 × 160 × 60

256 × 256 × 32

625

STIR

3200

48

90

 

4

5

180

256 × 256

703

T2 DSE

4080

106

  

3

2

160

256 × 256

625

Proton Density DSE

4080

26

  

3

2

160

256 × 256

625

High-field (9.4 T)

         

3 Dimensional GRE

3.2

2.65

 

5

 

8

70 × 70 × 35

256 × 256 × 128

274

    

10

     
    

20

     
    

40

     
    

60

     
    

90

     
  1. T: Tesla, TR: repetition time, TE: echo time, TI: inversion time, NEX: number of excitations, FOV: field of view, GRE: gradient echo, STIR: short tau inversion recovery, DSE: dual spin echo.